NVME-WRITE(1) NVMe Manual NVME-WRITE(1)
NAME
nvme-write - Send an NVMe write command, provide results
SYNOPSIS
nvme-write <device> [--start-block=<slba> | -s <slba>]
[--block-count=<nlb> | -c <nlb>]
[--data-size=<size> | -z <size>]
[--metadata-size=<size> | -y <size>]
[--ref-tag=<reftag> | -r <reftag>]
[--data=<data-file> | -d <data-file>]
[--metadata=<metadata-file> | -M <metadata-file>]
[--prinfo=<prinfo> | -p <prinfo>]
[--app-tag-mask=<appmask> | -m <appmask>]
[--app-tag=<apptag> | -a <apptag>]
[--limited-retry | -l] [--force-unit-access | -f]
[--dir-type=<type> | -T <type>]
[--dir-spec=<spec> | -S <spec>] [--dsm=<dsm> | -D <dsm>]
[--show-command | -V] [--dry-run | -w] [--latency | -t]
[--storage-tag<storage-tag> | -g <storage-tag>]
[--storage-tag-check | -C] [--force]
[--output-format=<fmt> | -o <fmt>] [--verbose | -v]
[--timeout=<timeout>]
DESCRIPTION
The Write command writes the logical blocks specified by the command to
the medium from the data data buffer provided. Will use stdin by default
if you don’t provide a file.
OPTIONS
-s <slba>, --start-block=<slba>
Start block.
-c, --block-count
The number of blocks to transfer. This is a zeroes based value to
align with the kernel’s use of this field. (ie. 0 means transfer 1
block).
-z <size>, --data-size=<size>
Size of data, in bytes.
-y <size>, --metadata-size=<size>
Size of metadata in bytes.
-d <data-file>, --data=<data-file>
Data file. If none provided, contents are sent from STDIN.
-M <metadata-file>, --metadata=<metadata-file>
Metadata file, if necessary.
-p <prinfo>, --prinfo=<prinfo>
Protection Information field definition.
┌─────┬────────────────────────────┐
│ Bit │ Description │
├─────┼────────────────────────────┤
│ 3 │ PRACT: Protection │
│ │ Information Action. When │
│ │ set to 1, PI is │
│ │ stripped/inserted on │
│ │ read/write when the block │
│ │ format’s metadata size is │
│ │ 8. When set to 0, metadata │
│ │ is passes. │
├─────┼────────────────────────────┤
│ 2:0 │ PRCHK: Protection │
│ │ Information Check: │
├─────┼────────────────────────────┤
│ 2 │ Set to 1 enables checking │
│ │ the guard tag │
├─────┼────────────────────────────┤
│ 1 │ Set to 1 enables checking │
│ │ the application tag │
├─────┼────────────────────────────┤
│ 0 │ Set to 1 enables checking │
│ │ the reference tag │
└─────┴────────────────────────────┘
-r <reftag>, --ref-tag=<reftag>
Optional reftag when used with protection information.
-m <appmask>, --app-tag-mask=<appmask>
Optional application tag mask when used with protection information.
-a <apptag>, --app-tag=<apptag>
Optional application tag when used with protection information.
-l, --limited-retry
Sets the limited retry flag.
-f, --force-unit-access
Set the force-unit access flag.
-T <type>, --dir-type=<type>
Optional directive type. The nvme-cli only enforces the value be in
the defined range for the directive type, though the NVMe
specification (1.3a) defines only one directive, 01h, for write
stream identifiers.
-S <spec>, --dir-spec=<spec>
Optional field for directive specifics. When used with write
streams, this value is defined to be the write stream identifier.
The nvme-cli will not validate the stream requested is within the
controller’s capabilities.
-D <dsm>, --dsm=<dsm>
The optional data set management attributes for this command. The
argument for this is the least significant 8 bits of the DSM field
in a write command; the most significant 16 bits of the field come
from the directive specific field, if used. This may be used to set
attributes for the LBAs being written, like access frequency, type,
latency, among other things, as well as yet to be defined types.
Please consult the NVMe specification for detailed breakdown of how
to use this field.
-V, --show-cmd
Print out the command to be sent.
-w, --dry-run
Do not actually send the command. If want to use --dry-run option,
--show-cmd option must be set. Otherwise --dry-run option will be
ignored.
-t, --latency
Print out the latency the IOCTL took (in us).
-g <storage-tag>, --storage-tag=<storage-tag>
Variable Sized Expected Logical Block Storage Tag(ELBST).
-C, --storage-tag-check
This flag enables Storage Tag field checking as part of end-to-end
data protection processing.
--force
Ignore namespace is currently busy and performed the operation even
though.
-o <fmt>, --output-format=<fmt>
Set the reporting format to normal, json or binary. Only one output
format can be used at a time.
-v, --verbose
Increase the information detail in the output.
--timeout=<timeout>
Override default timeout value. In milliseconds.
EXAMPLES
No examples yet.
NVME
Part of the nvme-user suite
NVMe 05/02/2025 NVME-WRITE(1)
Generated by dwww version 1.16 on Mon Nov 9 06:11:24 CET 2026.