dwww Home | Manual pages | Find package

SDPARM(8)                            SDPARM                           SDPARM(8)

NAME
       sdparm  - access SCSI modes pages; read VPD pages; send simple SCSI com-
       mands.

SYNOPSIS
       sdparm [--all]  [--dbd]  [--examine]  [--flexible]  [--get=STR]  [--hex]
       [--long]   [--num-desc]   [--out-mask=OM]   [--page=PG[,SPG]]  [--quiet]
       [--readonly] [--six] [--transport=TN] [--vendor=VN]  [--verbose]  DEVICE
       [DEVICE...]

       sdparm     [--clear=STR]     [--defaults]     [--dummy]     [--flexible]
       [--page=PG[,SPG]] [--quiet] [--readonly]  [--save]  [--set=STR]  [--six]
       [--transport=TN] [--vendor=VN] [--verbose] DEVICE [DEVICE...]

       sdparm  --command=CMD  [--hex]  [--long] [--readonly] [--verbose] DEVICE
       [DEVICE...]

       sdparm --inquiry [--all] [--examine] [--flexible]  [--hex]  [--num-desc]
       [--page=PG[,SPG]]  [--quiet]  [--readonly]  [--transport=TN] [--verbose]
       DEVICE [DEVICE...]

       sdparm  --enumerate  [--all]  [--inquiry]   [--long]   [--page=PG[,SPG]]
       [--transport=TN] [--vendor=VN]

       sdparm  --inhex=FN  [--all]  [--flexible]  [--hex]  [--inquiry] [--long]
       [--pdt=DT] [--raw] [--six] [--transport=TN] [--vendor=VN] [--verbose]

       sdparm --wscan [--verbose]

       sdparm [--help] [--version]

DESCRIPTION
       This utility fetches and potentially changes  SCSI  device  (e.g.  disk)
       mode  pages.  Inquiry  data including Vital Product Data (VPD) pages can
       also be displayed. Commands associated with starting  and  stopping  the
       medium;  loading  and unloading the medium; and other housekeeping func-
       tions may also be issued by this utility.

       The first invocation shown in the synopsis is for accessing (i.e.  read-
       ing)  mode page fields held on the DEVICE. The second form is for chang-
       ing mode page fields held on the DEVICE. The third form is for executing
       some simple SCSI commands. The fourth form  (i.e.   the  '--inquiry  ...
       DEVICE'  form) is for fetching and decoding VPD pages from the given DE-
       VICE. The --enumerate form is for listing out mode  or  VPD  field  data
       held  by this utility (and if a DEVICE is given then it is ignored). The
       --inhex=FN form decodes mode or VPD response data provided in the  named
       file  (or from stdin if FN=- is given); that data may either be in hexa-
       decimal or binary. The second last form is for Windows  only  and  lists
       the  available  storage device names; see the OPTIONS entry for --wscan.
       The final form is to provide command line help  or  the  version  number
       (and date) of this utility.

       If  no  options (other than DEVICE) are given then a selection of common
       mode page fields for that device are listed. If  the  --long  option  is
       also  given  then  a description of the fields is placed on the right of
       each line. If the --all option is given then all known mode page  fields
       for  that device are listed. Individual fields can be displayed with the
       --get=STR option (e.g. '--get=WCE' to fetch the state of  the  Writeback
       Cache Enable field).

       This  utility  completes  with  an exit status of 0 when successful. For
       other values see the EXIT STATUS section below.

       One or more DEVICE arguments can be given. The utility will  essentially
       apply  the  given  options to each DEVICE in the list. If a error is de-
       tected, it is noted and the utility continues. Error value 5 (file  open
       or close problem) is treated as lower priority when other errors are de-
       tected.  The  exit status is the most recently detected error value (ex-
       cluding error value 5 if other errors have been detected).  If  all  ac-
       tions succeed the exit status is zero.

       By  default  this utility shows mode pages that are common to all trans-
       port protocols. These are termed as "generic" mode pages. If there is no
       match on a generic mode page name or field then those pages specific  to
       the  SAS  transport are checked.  Transport protocol specific mode pages
       are selected with the --transport=TN option. See the  TRANSPORT  section
       below.  Vendor specific mode pages are selected with the --vendor=VN op-
       tion.  See the VENDORS section below.

       Although  originally  for  SCSI disks (or storage devices that appear to
       the OS as SCSI disks) many of the mode pages are for other  SCSI  device
       types.   These  include CD/DVD players that use the ATAPI (or any other)
       transport, SCSI tapes drives and SCSI enclosures.

       When the --inquiry option is given without a page number then the Device
       Identification VPD page (page number 0x83) is requested and if found  it
       is  decoded  and output. If no page number is given and the --all option
       is given then a list of VPD page names (but  not  their  contents)  sup-
       ported  by  the  DEVICE is output. When both the --inquiry and --page=PG
       options are given then the VPD page can be specified as an  abbreviation
       (e.g. "sp" for the SCSI ports VPD page) or numerically (e.g. "0x88"). If
       a  VPD page is returned by the DEVICE but sdparm cannot decode it or the
       --hex option is given then it is output in hex.

OPTIONS
       Mandatory arguments to long options are mandatory for short  options  as
       well.   If  an option takes a numeric argument then that argument is as-
       sumed to be decimal unless otherwise indicated (e.g. with a leading "0x"
       or a trailing "h"). The options are in alphabetical order, based on  the
       long option name.

       -a, --all
              output  all  recognized fields for the device type (e.g. disk) of
              the DEVICE. Without this option (or the  --page=PG[,SPG]  option)
              the default action is to output a relatively small number of com-
              monly  used  fields  from different pages. When a specific (mode)
              page number is given with the --page=PG[,SPG] option then all the
              fields of that page are output (irrespective of  the  setting  of
              this  option). For this option's action when used with the --enu-
              merate option see the ENUMERATE section below.
              When used together with the --inquiry option and  a  DEVICE,  the
              Supported VPD Pages VPD page [0x0] is output. When this option is
              used twice (short form: '-iaa') then all VPD pages (listed in the
              Supported VPD Pages VPD page) are output.
              By  default --inhex=FN will only decode the first mode page found
              in FN. With this option, more  mode  pages  will  be  decoded  if
              present. When --transport=TN or --vendor=VN is also given then if
              a  given  mode  page is not defined for that transport or vendor,
              then it is decoded as a generic mode page.

       -c, --clear=STR
              In its simplest form STR contains a field acronym_name or a field
              numerical descriptor. In the absence of an explicit  value  argu-
              ment  (e.g.  '--clear=WCE=1'), the field has its value cleared to
              zero.  See the PARAMETERS section below.

       -C, --command=CMD
              Perform given CMD. See section below on  COMMANDS.  To  enumerate
              supported  commands  use  '-e -C x' (using any CMD name, valid or
              otherwise).

       -B, --dbd
              disable block descriptors. This is a bit in MODE SENSE cdbs  that
              rarely  needs  to be set. One known case is a MODE SENSE 6 issued
              to a Reduced Block Commands (RBC) device where the  RBC  standard
              says it shall be set.

       -D, --defaults
              sets  the  given  mode  page  to its default values. Requires the
              --page=PG[,SPG] option to be given to specify the mode  page.  To
              make  the  default mode page values also the saved mode page val-
              ues, use the --save option as well.
              when this option is used twice, the current values in  all  modes
              pages  are  reverted  to  their defaults. If the --save option is
              given as well, then the current and saved  values  in  all  modes
              pages  are  reverted to their defaults. This feature uses the RTD
              bit in the MODE SELECT command which was added in draft SPC-5 re-
              vision 11.

       -d, --dummy
              when set inhibits changes being placed in the DEVICE's mode page.
              Instead the mode data that would have been sent to a MODE  SELECT
              command,  is  output  in ASCII hex to the console. This option is
              mainly for testing.

       -e, --enumerate
              lists out descriptive information  about  the  pages  and  fields
              known  to this utility. Ignores the DEVICE argument and other op-
              tions apart from the --all, --inquiry,  --long,  --page=PG[,SPG],
              --transport=TN  and  --vendor=VN. If --enumerate is given without
              other options then the known (generic)  mode  pages  are  listed.
              See the ENUMERATE section below.

       -E, --examine
              for  mode pages only those with known field names are probed when
              the --all option is given. For VPD pages only those pages  listed
              in  "Supported  VPD  pages  page" are decoded. In both cases some
              pages may be missed. With this option (i.e. --examine)  all  mode
              and VPD pages can be probed.
              For  mode  pages, this option will probe all mode pages from page
              number 0x0 to 0x3e. To probe mode subpages give a mode page  num-
              ber  with  --page=PG and then all subpages (from 0x0 to 0xfe) are
              probed.
              For VPD pages, use this option with --inquiry.  This  will  cause
              all  VPD  pages  from  0x0 to 0xbf to be probed by default. A se-
              quence of VPD pages can be probed with --page=PG[,SPG]  in  which
              case VPD pages from PG (lower number) to SPG (high number) inclu-
              sive  are probed. Vendor specific VPD pages run from 0xc0 to 0xff
              and can be probed by setting SPG from 0xc0 to 0xff.

       -f, --flexible
              Some devices, bridges and/or drivers  attempt  crude  transforma-
              tions between mode sense 6 and 10 byte commands without correctly
              rebuilding  the  response.   This  will  cause the response to be
              mis-interpreted (usually with an error  saying  the  response  is
              malformed).  With  this  option,  the  length  of the response is
              checked, and if it  looks  wrong,  various  corrections  are  at-
              tempted. This option will also allow mode pages that don't belong
              to the current device's peripheral type to be listed.

       -g, --get=STR
              In its simplest form STR contains a field acronym_name or a field
              numerical  descriptor.  The  field is fetched from mode page. See
              the PARAMETERS section below. The --long and --hex options effect
              the output format.  Also  if  a  value  of  "1"  is  given  (e.g.
              '--get=WCE=1')  only  the  current  value is output (i.e. not the
              change mask, the default value and the saved value).

       -h, --help
              output the usage message then exit.

       -H, --hex
              rather than trying to decode mode (or VPD) pages, print them  out
              in  hex.  When  used  with the --get=STR option the corresponding
              current, changeable, default and saved values are output in  hex,
              prefixed  by "0x" and space separated. If a value of "1" is given
              with the --get=STR option (e.g. '--get=WCE=1') then only the cur-
              rent value is output in hex, prefixed by "0x". If a value of  "2"
              is given with the --get=STR option then only the current value is
              output  as  a  (signed) integer. This option can be used multiple
              times (e.g. '-HH'). Useful with  the  ATA  Information  VPD  page
              which usually outputs its IDENTIFY (PACKET) DEVICE response in 16
              bit  hex  words;  with  '-HH' outputs that response in hex bytes;
              with '-HHH' outputs the same response in a  format  suitable  for
              'hdparm --Istdin' to decode.
              Mode  page  output with the '-HHH' option is suitable for a later
              invocation of sdparm with the --inhex=FN option.

       -i, --inquiry
              output a VPD page which is in the response of a SCSI INQUIRY com-
              mand sent to DEVICE. In the absence of this  option  the  default
              action  is to output mode pages. If the --inquiry option is given
              without the --page=PG[,SPG] option then the device identification
              VPD page (0x83) is decoded and output. If  this  option  and  the
              --all option are given then the supported VPD pages page (0x0) is
              decoded and output.

       -I, --inhex=FN
              FN  is  expected  to be a file name (or '-' for stdin) which con-
              tains ASCII hexadecimal (or binary) representing the response  to
              MODE  SENSE(10).   If  --six is also given then the response from
              MODE SENSE(6) is assumed. A MODE SENSE response contains  a  mode
              parameter  header,  then  0 or more block descriptors followed by
              one or more mode pages. This utility will only decode  the  first
              mode  page unless the --all option is given. In order to decode a
              mode page the peripheral device type is often needed and  can  be
              supplied  with  the --pdt=DT option. If the --pdt=DT is not given
              then a mode page found in two device type standards (e.g. SBC and
              SSC) may be decoded twice.
              If --inquiry is given then FN is interpreted as the response data
              of a single VPD page.
              The hexadecimal in FN should be arranged as 1 or 2 digits  repre-
              senting  a  byte  each of which is whitespace or comma separated.
              Anything from and including a hash mark to the end of line is ig-
              nored. If the --raw option is given then FN is treated as binary.

       -l, --long
              output extra information. In the case of mode page fields  a  de-
              scription  (with  units if applicable) is output to the right. If
              used twice, then for some fields more information about its  val-
              ues  is  given on one or more following lines, each prefixed by a
              tab character. For usage with --enumerate see the ENUMERATE  sec-
              tion below.
              When  this  option is used along with --command=capacity then the
              READ CAPACITY(16) is sent to the DEVICE and if successful its ex-
              tended response is output.

       -n, --num-desc
              for a mode page that can have descriptors, the number of descrip-
              tors for the given page on the DEVICE is output. Otherwise  0  is
              output.

       -o, --out-mask=OM
              OM  is  a  bit  mask  for  mode  page  selections  that  will  be
              printed/output.  The 0x1 value is for the 'current'  values,  0x2
              is  for  the 'changeable' values, 0x4 is for the 'default' values
              and 0x8 is for the 'saveable' values.  The default value  is  0xf
              (i.e.  the  OR  of all four values set). The option is useful for
              limiting the amount of output with the '-HHH'.

       -p, --page=PG[,SPG]
              supply the page number (PG) and optionally the  sub  page  number
              (SPG)  of  the mode (or VPD) page to fetch. These numbers are in-
              terpreted as decimal unless prefixed with "0x" or a trailing. Sub
              page numbers are only valid for mode pages (not VPD  pages).  Al-
              ternatively an abbreviation for a page can be given (see next en-
              try).

       -p, --page=STR
              a two or three letter abbreviation for a page can be given. Known
              mode  page  abbreviations are checked first followed by known VPD
              page abbreviations.  For example '--page=ca' matches the  caching
              mode  page.  If  no  match is found then an error is issued and a
              list of possibilities in the current context is given (so '-p  x'
              can  be quite useful). If the STR matches a known VPD page abbre-
              viation then the --inquiry option  is  assumed.  For  usage  with
              --enumerate see the ENUMERATE section below.

       -P, --pdt=DT
              This  option  is only active when the --inhex=FN option is given.
              DT is the peripheral Device Type, a value between 0  and  31  and
              can  be found in the response to the INQUIRY command. The default
              value is -1 (which may also be given for DT)  and  it  is  inter-
              preted  as  SPC  (i.e.  common  mode pages) or as a wild card. If
              available this option should be supplied with the --inhex=FN  op-
              tion.

       -q, --quiet
              suppress  output  of  device name followed by the vendor, product
              and revision strings fetched from an  INQUIRY  response.  Without
              this option such a line is typically the first line output by sd-
              parm.  Reduces  output  from  the device identification VPD page,
              typically to one line (or  none)  for  each  of  di_lu,  di_port,
              di_target and di_asis.
              If  this  option is used twice then additionally mode page output
              suppresses the changeable, default and saved values that are usu-
              ally shown in braces, if available.

       -r, --readonly
              override other logic to open DEVICE in read-only  mode.  The  de-
              fault  setting  of  the open read-only/read-write mode depends on
              the operation requested (e.g. a --set=STR  operation  by  default
              will  try  a  read-write mode open on DEVICE). This option may be
              useful if a command is being sent to an ATA disk via a SCSI  com-
              mand  set. For example in Linux '-C stop' may require this option
              to stop an ATA disk being restarted immediately.

       -R, --raw
              this option is only active when used with the --inhex=FN  option.
              When  this option is given then the file FN is interpreted as bi-
              nary; the default action (i.e. when this option is not given)  is
              to interpret FN as ASCII hexadecimal.

       -S, --save
              when  a  mode  page  is  being modified (by using the --clear=STR
              and/or --set=STR options) then the default action  is  to  modify
              only the current values mode page. When this option is given then
              the  corresponding value(s) in the saved values mode page is also
              changed. The next time the device is power cycled (or reset)  the
              saved  values  mode  page becomes (i.e. is copied to) the current
              values mode page. This option sets the SP field in the  MODE  SE-
              LECT command. See NOTES section below.

       -s, --set=STR
              in its simplest form STR contains a field acronym_name or a field
              numerical  descriptor.  In the absence of an explicit value, each
              acronym_name has its value set to (all) ones. This means a 16 bit
              field will be set to 0xffff which is 65535 in  decimal.  Alterna-
              tively  each acronym_name or numerical descriptor may be followed
              by "=<n>" where <n> is the value to set that field  to.  See  the
              PARAMETERS section below.

       -6, --six
              The  default  action  of  this utility is to issue MODE SENSE and
              MODE SELECT SCSI commands with 10 byte cdbs. When this option  is
              given  the 6 byte cdb variants are used. RBC and old SCSI devices
              may need this option. This utility outputs a  suggestion  to  use
              this  option  if  the  SCSI status indicates that the 10 byte cdb
              variant is not supported.
              The SPC-4 standard (and SPC-5 drafts) include a note stating that
              implementers migrate away from the SCSI MODE SELECT(6)  and  MODE
              SENSE(6)  commands  in favour of the 10 byte variants (e.g.  MODE
              SEMSE(10)).

       -t, --transport=TN
              Specifies the transport protocol where TN is either a  number  in
              the  range 0 to 15 (inclusive) or an abbreviation (e.g. "fcp" for
              the Fibre Channel Protocol). Some transports accept multiple  ab-
              breviations,  for  example srp (SCSI RDMA Protocol) and ib (short
              for InfiniBand) both are accepted for transport  protocol  0x4  .
              Also  both  upper  and lower case are accepted so iscsi and iSCSI
              are accepted for transport protocol 0x5 . One way to list  avail-
              able  transport  protocols numbers and their associated abbrevia-
              tions is to give an invalid transport protocol name such  as  '-t
              x';  another  way is '-e -l'.  N.B. The --all option may still be
              needed to show all available fields.

       -M, --vendor=VN
              Specifies the vendor (i.e. manufacturer) where  VN  is  either  a
              number  (0  or  more)  or an abbreviation (e.g. "sea" for Seagate
              disk vendor specific).  For tape drives  "lto5"  and  "lto6"  are
              treated  as vendors. One way to list the available vendor numbers
              and their associated abbreviations is to give an  invalid  vendor
              number such as '-M x'; another way is '-e -l'.
              This  option  only  effects mode page decodes, not VPD pages. For
              vendor specific VPD pages see the sg_vpd utility.

       -v, --verbose
              increase the level of verbosity, (i.e.  debug  output).  In  some
              cases  more  decoding  is done (e.g. fields within a standard IN-
              QUIRY response).

       -V, --version
              print the version string and then exit.

       -w, --wscan
              this option is available in Windows only. It lists storage device
              names and the corresponding volumes, if any. When used  twice  it
              adds the "bus type" of the closest transport (e.g. a SATA disk in
              a  USB  connected  enclosure  has  bus type Usb). When used three
              times a SCSI adapter scan is added. When used four times  only  a
              SCSI  adapter  scan  is shown.  See examples below and the "Win32
              port" section in the README file.

NOTES
       The reference document used for interpreting mode and VPD pages (and the
       INQUIRY standard response) is T10/BSR INCITS 502 Revision 17 (SPC-5,  19
       September  2017)  found  at  http://www.t10.org  . Obsolete and reserved
       items in the standard INQUIRY response output are displayed in brackets.
       Recent drafts of other T10 documents are also used: SBC-4 (disks), SSC-5
       (tapes), SPL-5 (SAS transport) and SAT-4 (SCSI to ATA Translation).

       A mode page for which no abbreviation is known (e.g. a  vendor  specific
       mode  page) can be listed in hexadecimal by using the option combination
       '--page=PG --hex'.

       Numbers input to sdparm (e.g. in the command line arguments) are assumed
       to be in decimal unless there is a hexadecimal indicator. A  hexadecimal
       indicator  is either a leading '0x' or '0X' (i.e. the C language conven-
       tion) or a trailing 'h' or 'H' (i.e. the convention used at  www.t10.org
       ).  In the case of --page= either a string or number is expected, so hex
       numbers like 'ch' (12) should be prefixed by a zero (e.g. '0ch').

       The SPC-4 draft (rev 2) says that devices that implement no  distinction
       between  current  and  saved pages can return an error (ILLEGAL REQUEST,
       invalid field in cdb) if the SP bit (which corresponds to the --save op-
       tion) is _not_ set. In such cases the --save option needs to be given.

       If the --save option is given but the existing mode page indicates  (via
       its  PS  bit) that the page is not saveable, then this utility generates
       an error message. That message suggests to try again without the  --save
       option.

       Since the device identification VPD page (acronym_name "di") potentially
       contains  a  lot of diverse designators, several associated acronyms are
       available. They are "di_lu" for  designators  associated  with  the  ad-
       dressed logical unit, "di_port" for designators associated with the tar-
       get port (which the command arrived via) and "di_target" for designators
       associated  with  the  target  device. When "di" is used designators are
       grouped by lu, then port and then target device.  To see all designators
       decoded in the order that they appear in the VPD page use "di_asis".

       Only those VPD pages defined by t10.org are  decoded  by  this  utility.
       SPC-4  sets aside VPD pages codes from 0xc0 to 0xff (inclusive) for ven-
       dor specific pages some of which are decoded in the sg_vpd utility.

       To see all VPD pages supported by a DEVICE use 'sg_vpd --all'.

       In the linux kernel 2.6 and 3 series any device node that understands  a
       SCSI  command  set (e.g. SCSI disks and CD/DVD drives) may be specified.
       More precisely the driver that "owns" the device node must  support  the
       SG_IO  ioctl.  In  the lk 2.4 series only SCSI generic (sg) device nodes
       support the SG_IO ioctl. However in the lk 2.4 series other SCSI  device
       nodes  are  mapped  within this utility to their corresponding sg device
       nodes. So if there is a SCSI disk at  /dev/sda  then  'sdparm  /dev/sda'
       will  work  in  both the lk 2.4 series and later. However if there is an
       ATAPI cd/dvd drive at /dev/hdc then 'sdparm /dev/hdc' will only work  in
       the lk 2.6 series and later.

       In  the  Linux 2.6 and 3 series, especially with ATA disks, using sdparm
       to stop (spin down) a disk may not be sufficient  and  other  mechanisms
       will  start  the disk again some time later. The user might additionally
       mark the disk as  "offline"  with  'echo  offline  >  /sys/block/sda/de-
       vice/state' where sda is the block name of the disk. To restart the disk
       "offline" can be replaced with "running".

PARAMETERS
       In their simplest form the --clear=, --get= and --set= options (or their
       short  forms)  take  an  acronym_name  such  as  "WCE".  In  the case of
       '--get=WCE' the value of "Writeback Cache Enable" in  the  caching  mode
       page  will  be  fetched. In the case of '--set=WCE' that bit will be set
       (to one). In the case of '--clear=WCE' that  bit  will  be  cleared  (to
       zero).  When an acronym_name is given then the mode page is imputed from
       that acronym_name (e.g. WCE is in the caching mode page).

       Instead of an acronym_name a field within a mode page can  be  described
       numerically  with a <start_byte>:<start_bit>:<num_bits> tuple. These are
       the <start_byte> (origin 0) within the mode page, a <start_bit> (0 to  7
       inclusive)  and  <num_bits>  (1  to  64 inclusive). For example, the low
       level representation of the RCD bit (the "Read Cache Disable bit in  the
       caching  mode page) is "2:0:1". The <start_byte> can optionally be given
       in hex (e.g. '--set=0x2:0:1' or  '--set=2h:0:1').  With  this  form  the
       --page= option is required to establish which mode page is to be used.

       Either  form can optionally be followed by "=<val>". By default <val> is
       decimal but can be given in hex in the normal fashion. Here are some ex-
       amples: '--set=2h:0:1=1h' and '-s MRIE=0x3'. When  the  acronym_name  or
       numeric  form  following --clear= is not given an explicit '=<val>' then
       the value defaults to zero. When the acronym_name or numeric  form  fol-
       lowing  --set= is not given an explicit '=<val>' then the value defaults
       to "all  ones"  (i.e.  as  many  as  <num_bits>  permits).  For  example
       '--clear=WCE' and '--clear=WCE=0' have the same meaning: clear Writeback
       Cache Enable or, put more simply: turn off the writeback cache.

       Multiple  fields  within  the  same mode page can be changed by giving a
       comma separated list of acronym_names and/or the numerical form. For ex-
       ample: '--set=TEST,MRIE=6'.

       Some mode page have multiple descriptors. They typically  have  a  fixed
       header  section at the start of the mode page that includes a field con-
       taining the number of descriptors that follow. Following the header is a
       variable number of descriptors. An example is the SAS  Phy  Control  and
       Discover  mode  page.  An  acronym_name  may include a trailing '.<num>'
       where "<num>" is a descriptor number (origin 0). For example '-t sas  -g
       PHID.0'  and '-t sas -g PHID' will yield the phy identifier of the first
       descriptor of the above mode page; '-t sas -g PHID.1' will yield the phy
       identifier of the second descriptor.

ENUMERATE
       The --enumerate option essentially dumps out static information held  by
       this  utility. A list of --enumerate variants and their actions follows.
       For brevity subsequent examples of options are shown  in  their  shorter
       form.

           --enumerate          list generic mode page information
           -e --all             list generic mode page contents
                                (i.e. parameters)
           -e --page=rw         list contents of read write error
                                recovery mode page
           -e --inquiry         list VPD pages this utility can decode
           -e --long            list generic mode pages, transport
                                protocols, mode pages for each
                                supported transport protocol and
                                supported commands
           -e -l --all          additionally list the contents of
                                each mode page
           -e --transport=fcp   list mode pages for the fcp
                                transport protocol
           -e -t fcp --all      additionally list the contents of
                                each mode page
           -e --vendor=sea      list vendor specific mode pages for
                                "sea" (Seagate)
           -e -M sea --all      additionally list the contents of vendor
                                specific mode pages for "sea" (Seagate)
           -e -p pcd -l         list contents of SAS phy control and
                                discovery mode page plus (due to "-l")
                                some descfriptor format information

       When known mode pages are listed (via the --enumerate  option) each line
       starts  with a two or three letter abbreviation. This is followed by the
       page number (in hex prefixed by "0x") optionally followed by a comma and
       the subpage number. Finally the descriptive name of the mode page  (e.g.
       as found in SPC-4) is output.

       When  known  parameters  (fields)  of  a mode page are listed, each line
       starts with an acronym (indented a few spaces). This will match  (or  be
       an  acronym  for)  the  description  for that field found in the (draft)
       standards. Next are three numbers, separated by  colons,  surrounded  by
       brackets. These are the start byte (in hex, prefixed by "0x") of the be-
       ginning of the field within the mode page; the starting bit (0 through 7
       inclusive)  and then the number of bits. The descriptive name of the pa-
       rameter (field) is then given. If appropriate the descriptive  name  in-
       cludes  units (e.g. "(ms)" means the units are milliseconds). Adding the
       '-ll' option will list information about possible field values  for  se-
       lected mode page parameters.

       Mode  parameters  for which the num_bits is greater than 1 can be viewed
       as unsigned integers. Often 16 and 32 bit fields are set to  0xffff  and
       0xffffffff  respectively  (all ones) which usually has a special meaning
       (see drafts). This utility outputs such values as  "-1"  to  save  space
       (rather than their unsigned integer equivalents). "-1" can also be given
       as the value to a mode page field acronym (e.g. '--set=INTT=-1' sets the
       interval  timer  field in the Informational Exceptions control mode page
       to 0xffffffff).

TRANSPORTS
       SCSI transport protocols are a relatively specialized area that  can  be
       safely ignored by the majority of users.

       Some  transport  protocols  have protocol specific mode pages. These are
       usually the disconnect-reconnect (0x2), the  protocol  specific  logical
       unit  (0x18)  and  the protocol specific port (0x19) mode pages. In some
       cases the latter mode page has several subpages. The most common  trans-
       port  protocol  abbreviations  likely  to  be  used are "fcp", "spi" and
       "sas".

       Many of the field  names  are  re-used  in  the  same  position  so  the
       acronym_name  namespaces  have  been  divided between generic mode pages
       (i.e. when the --transport= option is _not_ given) and a  namespace  for
       each  transport protocol. A LUPID field from the protocol specific logi-
       cal unit (0x18) mode page and the PPID field from protocol specific port
       (0x19) mode page are included in the generic modes pages; this is so the
       respective (transport) protocol identifiers can be seen. In  most  cases
       the user will know what the "port" transport is (i.e. the same transport
       as  the  HBA  in the computer) but the logical unit's transport could be
       different.

VENDORS
       SCSI leaves a lot of space for vendor specific information.  Often  this
       is  described  in product manuals. The --vendor=VN (or -M=VN) option al-
       lows known vendor specific mode pages to be examined and/or modified  by
       acronym.

       In  this  utility the syntax and semantics of vendor specific mode pages
       is very similar to those of transport protocol specific mode pages. Both
       cannot be specified together. Vendor specific modes pages can  still  be
       accessed numerically (as shown at the end of the EXAMPLES section).

COMMANDS
       The  command  option  sends a SCSI command to the DEVICE. If the command
       fails then this is reflected in the non-zero  exit  status.   To  obtain
       more information about the error use the -v option.

       capacity
              sends a READ CAPACITY(10) command (valid for disks and cd/dvd me-
              dia)  by  default. If successful yields "blocks: " [the number of
              blocks], "block_length: " [typically either 512 or 2048] and "ca-
              pacity_mib: " [capacity in MibiBytes (1048576 byte units)].

       If the number of blocks is too large to fit in the 4 byte field provided
       by READ CAPACITY(10) or, the --long option is given, then the  READ  CA-
       PACITY(16)  command is sent. If the --long option is given, then the ex-
       tra fields found in the READ CAPACITY(16) response are output.

       eject  stops the medium and ejects it from the device.  Note that  ejec-
              tion  (by  command  or button) may be prevented in which case the
              'unlock' command may be useful in extreme cases.  Typically  only
              appropriate  for cd/dvd drives and disk drives with removable me-
              dia. Objects if sent to another peripheral device type  (but  ob-
              jection can be overridden with '-f' option).

       load   loads  the  medium  and starts it (i.e. spins it up). See 'eject'
              command for supported device types.

       profile
              lists the various formats that a CD/DVD/HD-DVD/BD drive supports.
              These are called "profiles" in the MMC standard. The profiles are
              listed one per line.  If media is in the drive then  the  profile
              that  matches  the  media (if any) has an "*" to the right of the
              line.

       ready  sends the "Test Unit Ready" SCSI command to the DEVICE. No  error
              is  reported  if  the  device will respond to data requests (e.g.
              READ) in a reasonable  timescale.  For  example,  if  a  disk  is
              stopped  then  it will report "not ready". All devices should re-
              spond to this command.

       sense  sends a REQUEST SENSE command. It reports  a  hardware  threshold
              exceeded,  warning  or  low  power  condition  if  flagged.  If a
              progress indication is present (e.g. during  a  format)  then  it
              will  be  output as a percentage. Yields a process status of 0 if
              the command succeeds and the sense key is 0; else yields  1.  The
              --quiet  option can be used to lessen output, and --hex to output
              sense data in hex.

       speed=SPEED
              permits the speed of a CD, DVD, HD_DVD or BD disc in a  drive  to
              be  set  (or  at  least  influenced).  It has this format: --com-
              mand=speed=SPEED where SPEED is in kilobytes per second. In  this
              case  a kilobyte is 1000 bytes. The "times one" speed for a CD is
              176.4 kB/s, for a DVD is 1350 kB/s and for both HD-DVD and BD  it
              is 4500 kB/s. If SPEED is zero then the drive is set to the speed
              that  it considers gives optimal performance.  This command sends
              a SET STREAMING multi-media command (MMC) to the drive.  The  EX-
              ACT  bit is clear so the drive will round the given SPEED as nec-
              essary.  The command is designed to control read  speed;  setting
              write speed should be left to "burning" programs.

       start  starts  the medium (i.e. spins it up). Harmless if medium has al-
              ready been started. See  'eject'  command  for  supported  device
              types. If the DEVICE is an ATA disk in Linux the '--readonly' op-
              tion may be required.

       stop   stops the medium (i.e. spins it down). Harmless if medium has al-
              ready  been  stopped.  See  'eject'  command for supported device
              types. If the DEVICE is an ATA disk in Linux the '--readonly' op-
              tion may be required. See the NOTES section above.

       sync   sends a SYNCHRONIZE CACHE command. The device  should  flush  any
              data held in its (volatile) buffers to the media.

       unlock tells a device to allow medium removal. It uses the SCSI "prevent
              allow  medium removal" command. This is desperation stuff, possi-
              bly overriding a prevention applied by the OS on a  mounted  file
              system.  The  "eject"  utility (from the "eject" package) is more
              graceful and should be tried first. This command is  only  appro-
              priate for devices with removable media.

       For  loading  and ejecting tapes the mt utility should be used (i.e. not
       these commands). The 'ready' command is valid for tape devices.

EXAMPLES
       To list the common (generic) mode parameters of a disk:

          sdparm /dev/sda

       To list the designators within the device identification VPD page  of  a
       disk:

          sdparm --inquiry /dev/sda

       To see all parameters for the caching mode page:

          sdparm --page=ca /dev/sda

       To  see all parameters for the caching mode page with parameter descrip-
       tions to the right:

          sdparm --page=ca --long /dev/sda

       To get the WCE values (current changeable default and saved) in hex:

          sdparm -g WCE -H /dev/sda
       0x01 0x00 0x01 0x01

       To get the WCE current value in hex:

          sdparm -g WCE=1 -H /dev/sda
       0x01

       To set the "Writeback Cache Enable" bit in the current values page:

          sdparm --set=WCE /dev/sda

       To set the "Writeback Cache Enable" bit in the current and saved  values
       page:

          sdparm --set=WCE --save /dev/sda

       To set the "Writeback Cache Enable" and clear "Read Cache Disable":

          sdparm --set=WCE --clear=RCD --save /dev/sda

       The previous example can also by written as:

          sdparm -s WCE=1,RCD=0 -S /dev/sda

       To  re-establish  the  manufacturer's  defaults in the current and saved
       values of the caching mode page:

          sdparm --page=ca --defaults --save /dev/sda

       If an ATAPI cd/dvd drive is at /dev/hdc then its common  (mode)  parame-
       ters could be listed in the lk 2.6 and 3 series with:

          sdparm /dev/hdc

       If  there  is a DVD in the drive at /dev/hdc then it could be ejected in
       the lk 2.6 and 3 series with:

          sdparm --command=eject /dev/hdc

       If the ejection is being prevented by software then that can be overrid-
       den with:

          sdparm --command=unlock /dev/hdc

       One disk vendor has a "Performance Mode" bit (PM) in the vendor specific
       unit attention mode page [0x0,0x0]. PM=0 is server  mode  (the  default)
       while  PM=1  is  desktop mode. Desktop mode can be set (both current and
       saved values) with:

          sdparm --page=0 --set=2:7:1=1 --save /dev/sda

       The resultant change can be viewed in hex with the --hex option as there
       are no acronyms for vendor extensions yet. The PM bit is now covered  by
       vendor specific mode pages and the above can also be accomplished with:

          sdparm --vendor=sea --set=PM --save /dev/sda

       What  follows are some examples from Windows using the '--wscan' option.
       The idea is to list the storage device names on the system that might be
       invoked by other uses of sdparm.

         # sdparm --wscan
       PD0     [C]     FUJITSU   MHY2160BH         0000
       PD1     [DF]    WD        2500BEV External  1.05  WD-WXE90
       CDROM0  [E]     MATSHITA DVD/CDRW UJDA775  CB03

       So 'sdparm -a CDROM0' and 'sdparm -a E' will show all the  (known)  mode
       page fields for the Matshita DVD/CD drive. By using the '--wscan' option
       twice, the bus type (as seen by the OS) is added to the output:

         # sdparm -ww
       PD0     [C]     <Ata  >  FUJITSU   MHY2160BH         0000
       PD1     [DF]    <Usb  >  WD        2500BEV External  1.05  WD-WXE90
       CDROM0  [E]     <Atapi>  MATSHITA DVD/CDRW UJDA775  CB03

       And the pattern continues to add a SCSI adapter scan. This may be useful
       if  there  are specialized storage related devices (e.g. a SES device in
       an enclosure) but does add much extra information in this case.

         # sdparm -www
       PD0     [C]     <Ata  >  FUJITSU   MHY2160BH         0000
       PD1     [DF]    <Usb  >  WD        2500BEV External  1.05  WD-WXE90
       CDROM0  [E]     <Atapi>  MATSHITA DVD/CDRW UJDA775  CB03

       SCSI0:0,0,0   claimed=1 pdt=0h  FUJITSU   MHY2160BH         0000
       SCSI1:0,0,0   claimed=1 pdt=5h  MATSHITA  DVD/CDRW UJDA775  CB03

EXIT STATUS
       To aid scripts that call sdparm, the exit status is set to indicate suc-
       cess (0) or failure (1 or more). Note that some of the lower values cor-
       respond to the SCSI sense key values. The exit status values are:

       0      success

       1      syntax error. Either illegal command line options,  options  with
              bad arguments or a combination of options that is not permitted.

       2      the  DEVICE  reports  that  it is not ready for the operation re-
              quested. The device may be in the process of becoming ready (e.g.
              spinning up but not at speed) so the utility  may  work  after  a
              wait.

       3      the DEVICE reports a medium or hardware error (or a blank check).
              For  example  an attempt to read a corrupted block on a disk will
              yield this value.

       5      the DEVICE reports an "illegal request" with an additional  sense
              code  other  than  "invalid operation code". This is often a sup-
              ported command with a field set requesting an  unsupported  capa-
              bility.  For  commands that require a "service action" field this
              value can indicate that the command is not supported.

       6      the DEVICE reports a "unit attention" condition. This usually in-
              dicates that something unrelated to the requested command has oc-
              curred (e.g. a device reset) potentially before the current  SCSI
              command  was sent. The requested command has not been executed by
              the device. Note that unit attention conditions are usually  only
              reported once by a device.

       7      the  DEVICE reports a "data protect" sense key. This implies some
              mechanism has blocked writes (or possibly all access to  the  me-
              dia).

       9      the  DEVICE  reports  an illegal request with an additional sense
              code of "invalid operation code" which means that it doesn't sup-
              port the requested command.

       10     the DEVICE reports a "copy aborted". This implies another command
              or device problem has stopped a copy operation. The EXTENDED COPY
              family of commands (including WRITE USING TOKEN) may return  this
              sense key.

       11     the DEVICE reports an aborted command. In some cases aborted com-
              mands  can  be retried immediately (e.g. if the transport aborted
              the command due to congestion).

       14     the DEVICE reports a miscompare sense key. VERIFY and COMPARE AND
              WRITE commands may report this.

       15     the utility is unable to open, close or  use  the  given  DEVICE.
              The given file name could be incorrect or there may be permission
              problems. Adding the -v option may give more information.

       20     the DEVICE reports it has a check condition but "no sense".  Some
              polling  commands (e.g. REQUEST SENSE) can react this way.  It is
              unlikely that this value will occur as an exit status.

       21     the DEVICE reports a "recovered error". The requested command was
              successful. Most likely a utility will report a  recovered  error
              to stderr and continue, probably leaving the utility with an exit
              status of 0 .

       22     the DEVICE reports that the current command or its parameters im-
              ply a logical block address (LBA) that is out of range.

       24     the  DEVICE reports a SCSI status of "reservation conflict". This
              means access to the DEVICE with  the  current  command  has  been
              blocked because another machine (HBA or SCSI "initiator") holds a
              reservation  on  this  DEVICE. On modern SCSI systems this is re-
              lated to the use of the PERSISTENT  RESERVATION  family  of  com-
              mands.

       25     the  DEVICE  reports  a SCSI status of "condition met". Currently
              only the PRE-FETCH command (see SBC-4) yields this status.

       26     the DEVICE reports a SCSI status of "busy".  SAM-5  defines  this
              status  as  the  logical  unit is temporarily unable to process a
              command.  It is recommended to re-issue the command.

       27     the DEVICE reports a SCSI status of "task set full".

       28     the DEVICE reports a SCSI status of "ACA active".  ACA  is  "auto
              contingent allegiance" and is seldom used.

       29     the  DEVICE  reports a SCSI status of "task aborted". SAM-5 says:
              "This status shall be returned if a command is aborted by a  com-
              mand  or  task  management  function on another I_T nexus and the
              Control mode page TAS bit is set to one".

       33     the command sent to DEVICE has timed out. This  occurs  in  Linux
              only; in other ports a command timeout will appear as a transport
              (or OS) error.

       40     the  command  sent  to  DEVICE  has received an "aborted command"
              sense key with an additional sense code of 0x10.  This  value  is
              related  to problems with protection information (PI or DIF). For
              example this error may occur when reading a block on a drive that
              has never been written (or is unmapped) if that drive was format-
              ted with type 1, 2 or 3 protection.

       48     this is an internal message indicating a NVMe status  field  (SF)
              is  other than zero after a command has been executed (i.e. some-
              thing went wrong).  Work in this area is currently experimental.

       49     low level driver reports a response's residual count (i.e. number
              of bytes actually received by HBA is  'requested_bytes  -  resid-
              ual_count') that is too high. So no useful processing can be done
              with that response.

       50 + <os_error_number>
              OS  system calls that fail often return a small integer number to
              help indicate what the error is. For example in Unix the  inabil-
              ity  of  a  system  call  to allocate memory returns (in 'errno')
              ENOMEM which often is associated with the integer 12. So 62 (i.e.
              '50 + 12') may be returned by a utility in this case.

       97     the response to a SCSI command failed sanity checks.

       98     the DEVICE reports it has a check condition but the error doesn't
              fit into any of the above categories.

       99     any errors that can't be categorized into  values  1  to  98  may
              yield  this  value.  This includes transport and operating system
              errors after the command has been sent to the device.

       126    the utility was found but could not be executed. That might occur
              if the executable does not have execute permissions.

       127    This is the exit status for utility not found. That  might  occur
              when  a script calls a utility in this package but the PATH envi-
              ronment variable has not been properly set up, so the script can-
              not find the executable.

       128 + <signum>
              If a signal kills a utility then the exit status is 128 plus  the
              signal  number. For example if a segmentation fault occurs then a
              utility is typically killed by SIGSEGV which according to 'man  7
              signal' has an associated signal number of 11; so the exit status
              will be 139 .

       255    the  utility tried to yield an exit status of 255 or larger. That
              should not happen; given here for completeness.

       Most of the error conditions reported above will be repeatable (an exam-
       ple of one that is not is "unit attention") so the utility  can  be  run
       again with the -v option (or several) to obtain more information.

AUTHORS
       Written by Douglas Gilbert.

REPORTING BUGS
       Report bugs to <dgilbert at interlog dot com>.

COPYRIGHT
       Copyright © 2005-2021 Douglas Gilbert
       This  software  is distributed under a FreeBSD license. There is NO war-
       ranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.

WEB SITE
       There    is    a    web    page    discussing    this     package     at
       https://sg.danny.cz/sg/sdparm.html .

SEE ALSO
       hdparm(hdparm),  sg_modes,  sg_wr_mode,  sginfo,  sg_inq,  sg_vpd(all in
       sg3_utils),      smartmontools(smartmontools.sourceforge.net),       mt,
       eject(eject),

sdparm-1.12                        April 2021                         SDPARM(8)