dwww Home | Manual pages | Find package

sane(7)                   SANE Scanner Access Now Easy                  sane(7)

NAME
       sane - Scanner Access Now Easy: API for accessing scanners

DESCRIPTION
       SANE  is  an application programming interface (API) that provides stan-
       dardized access to any raster image scanner hardware.  The  standardized
       interface  makes  it  possible to write just one driver for each scanner
       device instead of one driver for each scanner and application.

       While SANE is primarily targeted at a UNIX environment, the standard has
       been carefully designed to make it possible to implement the API on vir-
       tually any hardware or operating system.

       This manual page provides a summary of the information  available  about
       SANE.

       If  you  have  trouble  getting your scanner detected, read the PROBLEMS
       section.

TERMINOLOGY
       An application that uses the SANE interface is called a  SANE  frontend.
       A driver that implements the SANE interface is called a SANE backend.  A
       meta backend provides some means to manage one or more other backends.

SOFTWARE PACKAGES
       The  package  sane-backends contains backends, documentation, networking
       support, and the command line frontend scanimage(1).  The frontends  xs-
       canimage(1),  xcam(1),  and  scanadf(1)  are  included  in  the  package
       sane-frontends.  Both packages can be downloaded from the SANE  homepage
       (http://www.sane-project.org/).   Information  about other frontends and
       backends can also be found on the SANE homepage.

GENERAL INFORMATION
       The following sections provide short descriptions and links to more  in-
       formation about several aspects of SANE.  A name with a number in paren-
       thesis  (e.g.   sane-dll(5))  points  to  a  manual  page.  In this case
       man 5 sane-dll will display the page. Entries  like  /usr/share/doc/lib-
       sane/README  are  references  to text files that were copied to the SANE
       documentation directory (/usr/share/doc/libsane/)  during  installation.
       Everything else is a URL to a resource on the web.

       SANE homepage
         Information  on all aspects of SANE including a tutorial and a link to
         the   SANE   FAQ   can   be    found    on    the    SANE    homepage:
         http://www.sane-project.org/.

       SANE device lists
         The  SANE  device  lists  contain information about the status of SANE
         support for a specific device. If your scanner  is  not  listed  there
         (either  supported or unsupported), please contact us. See section HOW
         CAN YOU HELP SANE for details. There are lists for  specific  releases
         of  SANE,  for  the  current  development version and a search engine:
         http://www.sane-project.org/sane-supported-devices.html.   The   lists
         are also installed on your system at /usr/share/doc/libsane/.

       SANE mailing list
         There  is  a mailing list for the purpose of discussing the SANE stan-
         dard and its implementations: sane-devel.  Despite its name, the  list
         is  not  only  intended  for developers, but also for users. There are
         also some more lists for special topics. However, for users,  sane-de-
         vel   is   the   right   list.   How  to  subscribe  and  unsubscribe:
         http://www.sane-project.org/mailing-lists.html.

       SANE IRC channel
         The IRC (Internet Relay Chat) channel #sane can be found on the Freen-
         ode network (irc.libera.chat).  It's  for  discussing  SANE  problems,
         talking  about  development  and general SANE related chatting. Before
         asking for help, please read the other documentation mentioned in this
         manual page. The channel's topic is also  used  for  announcements  of
         problems with SANE infrastructure (mailing lists, web server, etc.).

       Compiling and installing SANE
         Look  at  /usr/share/doc/libsane/README  and  the  os-dependent README
         files for information about compiling and installing SANE.

       SCSI configuration
         For  information  about  various  systems  and  SCSI  controllers  see
         sane-scsi(5).

       USB configuration
         For information about USB configuration see sane-usb(5).

FRONTENDS AND MISCELLANEOUS PROGRAMS
       scanimage
         Command-line frontend. See scanimage(1).

       saned
         SANE  network daemon that allows remote clients to access image acqui-
         sition devices available on the local host. See saned(8).

       sane-find-scanner
         Command-line tool to find SCSI and USB scanners  and  determine  their
         UNIX device files. See sane-find-scanner(1).

       Also, have a look at the sane-frontends package (which includes xscanim-
       age(1),  xcam(1),  and  scanadf(1)) and the frontend information page at
       http://www.sane-project.org/sane-frontends.html.

BACKENDS FOR SCANNERS
       abaton
         Supports Abaton flatbed scanners such as the Scan  300/GS  (8bit,  256
         levels  of  gray)  and the Scan 300/S (black and white, untested). See
         sane-abaton(5) for details.

       agfafocus
         Supports AGFA Focus scanners and the Siemens  S9036  (untested).   See
         sane-agfafocus(5) for details.

       apple
         Supports  Apple flatbed scanners including the following scanners: Ap-
         pleScanner, OneScanner and ColorOneScanner. See sane-apple(5) for  de-
         tails.

       artec
         Supports  several  Artec/Ultima  SCSI  flatbed scanners as well as the
         BlackWidow BW4800SP and the Plustek 19200S. See sane-artec(5) for  de-
         tails.

       artec_eplus48u
         Supports  the Artec E+ 48U scanner and re-badged models like Tevion MD
         9693, Medion MD 9693, Medion MD 9705 and Trust Easy Webscan 19200. See
         sane-artec_eplus48u(5) for details.

       as6e
         Supports  the  Artec  AS6E  parallel  port  interface   scanner.   See
         sane-as6e(5) for details.

       avision
         Supports several Avision based scanners including the original Avision
         scanners (like AV 630, AV 620, ...) as well as the HP ScanJet 53xx and
         74xx  series,  Fujitsu  ScanPartner, some Mitsubishi and Minolta film-
         scanners.  See sane-avision(5) for details.

       bh
         Supports  Bell+Howell  Copiscan  II  series  document  scanners.   See
         sane-bh(5) for details.

       canon
         Supports  the  CanoScan  300,  CanoScan  600,  and CanoScan 2700F SCSI
         flatbed scanners. See sane-canon(5) for details.

       canon630u
         Supports   the   CanoScan   630u   and   636u   USB   scanners.    See
         sane-canon630u(5) for details.

       canon_dr
         Supports   the   Canon  DR-Series  ADF  SCSI  and  USB  scanners.  See
         sane-canon_dr(5) for details.

       canon_lide70
         Supports  the  CanoScan  LiDE   70   and   600   USB   scanners.   See
         sane-canon_lide70(5) for details.

       canon_pp
         Supports  the  CanoScan  FB330P, FB630P, N340P and N640P parallel port
         scanners.  See sane-canon_pp(5) for details.

       cardscan
         Support for Corex Cardscan USB scanners. See sane-cardscan(5) for  de-
         tails.

       coolscan coolscan2 coolscan3
         Supports   Nikon   Coolscan   film-scanners.   See   sane-coolscan(5),
         sane-coolscan2(5) and sane-coolscan3(5) for details.

       epjitsu
         Supports Epson-based Fujitsu USB scanners. See sane-epjitsu(5) for de-
         tails.

       epson
         Old driver for Epson SCSI, parallel port and USB flatbed scanners. See
         sane-epson(5) for details but try epson2 first.

       epson2
         Newer driver for Epson SCSI, parallel port, network  and  USB  flatbed
         scanners (try this before epson which is outdated). See sane-epson2(5)
         for details.

       escl
         Supports  scanners through the eSCL protocol. See sane-escl(5) for de-
         tails.

       fujitsu
         Supports most Fujitsu SCSI and USB,  flatbed  and  adf  scanners.  See
         sane-fujitsu(5) for details.

       genesys
         Supports  several  scanners  based  on the Genesys Logic GL646, GL841,
         GL843, GL847 and GL124 chips like the Medion 6471 and  Hewlett-Packard
         2300c.  See sane-genesys(5) for details.

       gt68xx
         Supports  scanners  based  on  the Grandtech GT-6801 and GT-6816 chips
         like the Artec Ultima 2000 and several Mustek BearPaw CU and  TA  mod-
         els.
         Some  Genius,  Lexmark, Medion, Packard Bell, Plustek, and Trust scan-
         ners are also supported. See sane-gt68xx(5) for details.

       hp
         Supports Hewlett-Packard ScanJet scanners which utilize  SCL  (Scanner
         Control Language by HP). See sane-hp(5) for details.

       hpsj5s
         Supports  the  Hewlett-Packard  ScanJet 5S scanner. See sane-hpsj5s(5)
         for details.

       hp3500
         Supports the Hewlett-Packard ScanJet 3500 series.  See  sane-hp3500(5)
         for details.

       hp3900
         Supports  the  Hewlett-Packard ScanJet 3900 series. See sane-hp3900(5)
         for details.

       hp4200
         Supports the Hewlett-Packard ScanJet 4200 series.  See  sane-hp4200(5)
         for details.

       hp5400
         Supports  the Hewlett-Packard ScanJet 54XXC series. See sane-hp5400(5)
         for details.

       hpljm1005
         Supports   the   Hewlett-Packard   LaserJet   M1005    scanner.    See
         sane-hpljm1005(5) for details.

       hs2p
         Supports the Ricoh IS450 family of SCSI scanners. See sane-hs2p(5) for
         details.

       ibm
         Supports  some  IBM  and  Ricoh SCSI scanners. See sane-ibm(5) for de-
         tails.

       kodak
         Supports some large Kodak scanners. See sane-kodak(5) for details.

       kodakaio
         Supports Kodak AiO printer/scanners. See sane-kodakaio(5) for details.

       kvs1025
         Supports Panasonic KV-S102xC scanners.  See  sane-kvs1025(5)  for  de-
         tails.

       leo
         Supports  the  LEO S3 and the Across FS-1130, which is a re-badged LEO
         FS-1130 scanner. See sane-leo(5) for details.

       lexmark
         Supports the Lexmark X1100 series of USB scanners. See sane-lexmark(5)
         for details.

       lexmark_x2600
         Supports the Lexmark X2600  series  of  USB  scanners.  See  sane-lex-
         mark_x2600(5) for details.

       ma1509
         Supports   the   Mustek   BearPaw   1200F  USB  flatbed  scanner.  See
         sane-ma1509(5) for details.

       magicolor
         Supports  the   KONICA   MINOLTA   magicolor   1690MF   multi-function
         printer/scanner/fax. See sane-magicolor(5) for details.

       matsushita
         Supports  some  Panasonic  KVSS  high  speed  scanners.  See sane-mat-
         sushita(5) for details.

       microtek
         Supports "second generation" Microtek  scanners  with  SCSI-1  command
         set. See sane-microtek(5) for details.

       microtek2
         Supports  some  Microtek  scanners  with  a  SCSI-2  command  set. See
         sane-microtek2(5) for details.

       mustek
         Supports most Mustek SCSI flatbed scanners including the  Paragon  and
         ScanExpress  series  and  the  600 II N and 600 II EP (non-SCSI). Some
         Trust scanners are also supported. See sane-mustek(5) for details.

       mustek_pp
         Supports Mustek parallel port flatbed scanners. See  sane-mustek_pp(5)
         for details.

       mustek_usb
         Supports   some   Mustek   ScanExpress   USB   flatbed  scanners.  See
         sane-mustek_usb(5) for details.

       mustek_usb2
         Supports scanners using the SQ113 chipset like the Mustek BearPaw 2448
         TA Pro USB flatbed scanner. See sane-mustek_usb2(5) for details.

       nec
         Supports the NEC PC-IN500/4C SCSI scanner.  See  sane-nec(5)  for  de-
         tails.

       niash
         Supports  the Agfa Snapscan Touch and the HP ScanJet 3300c, 3400c, and
         4300c USB flatbed scanners. See sane-niash(5) for details.

       p5
         Supports the Primax PagePartner. See sane-p5(5) for details.

       pie
         Supports Pacific Image Electronics (PIE) and Devcom SCSI flatbed scan-
         ners. See sane-pie(5) for details.

       pixma
         Supports Canon PIXMA MP series (multi-function devices), Canon  image-
         CLASS  series  (laser  devices),  Canon  MAXIFY  series and some Canon
         CanoScan series. See sane-pixma(5) for details.

       plustek
         Supports USB flatbed scanners  that  use  the  National  Semiconductor
         LM983[1/2/3]  chipset aka Merlin. Scanners using this LM983x chips in-
         clude some models from Plustek, KYE/Genius,  Hewlett-Packard,  Mustek,
         Umax, Epson, and Canon. See sane-plustek(5) for details.

       plustek_pp
         Supports Plustek parallel port flatbed scanners using the Plustek ASIC
         P96001,  P96003,  P98001  and  P98003, which includes some models from
         Plustek, KYE/Genius, Primax. See sane-plustek_pp(5) for details.

       ricoh
         Supports the Ricoh flatbed scanners IS50 and IS60.  See  sane-ricoh(5)
         for details.

       ricoh2
         Supports   the  Ricoh  flatbed  scanners:  SG-3100SNw,  SP-100SU,  and
         SP-111SU. See sane-ricoh2(5) for details.

       s9036
         Supports Siemens 9036 flatbed scanners. See sane-s9036(5) for details.

       sceptre
         Supports the Sceptre S1200 flatbed scanner.  See  sane-sceptre(5)  for
         details.

       sharp
         Supports Sharp SCSI scanners. See sane-sharp(5) for details.

       sm3600
         Supports  the  Microtek ScanMaker 3600 USB scanner. See sane-sm3600(5)
         for details.

       sm3840
         Supports the Microtek ScanMaker 3840 USB scanner.  See  sane-sm3840(5)
         for details.

       snapscan
         Supports  AGFA  SnapScan flatbed scanners including some which are re-
         badged to other brands. See sane-snapscan(5) for details.

       sp15c
         Supports  the  Fujitsu  FCPA  ScanPartner  15C  flatbed  scanner.  See
         sane-sp15c(5) for details.

       st400
         Supports the Siemens ST400 and ST800. See sane-st400(5) for details.

       tamarack
         Supports  Tamarack Artiscan flatbed scanners. See sane-tamarack(5) for
         details.

       teco1 teco2 teco3
         Supports some TECO scanners, usually sold under  the  Relisys,  Trust,
         Primax,  Piotech,  Dextra  names. See sane-teco1(5), sane-teco2(5) and
         sane-teco3(5) for details.

       u12
         Supports USB flatbed scanners based on Plustek's ASIC 98003 (parallel-
         port ASIC) and a GeneSys Logics'  USB-parport  bridge  chip  like  the
         Plustek OpticPro U(T)12. See sane-u12(5) for details.

       umax
         Supports  UMAX-SCSI-scanners and some Linotype Hell SCSI-scanners. See
         sane-umax(5) for details.

       umax_pp
         Supports Umax parallel port flatbed scanners and  the  HP  3200C.  See
         sane-umax_pp(5) for details.

       umax1200u
         Supports the UMAX Astra 1220U (USB) flatbed scanner (and also the UMAX
         Astra 2000U, sort of). See sane-umax1220u(5) for details.

       xerox_mfp
         Supports multiple Samsung-based Samsung, Xerox, and Dell scanners. See
         sane-xerox_mfp(5) for details.

       Also,    have    a   look   at   the   backend   information   page   at
       http://www.sane-project.org/sane-supported-devices.html and the list  of
       projects in /usr/share/doc/libsane/PROJECTS.

BACKENDS FOR DIGITAL CAMERAS
       dc210
         Supports the Kodak DC210 Digital Camera. See sane-dc210(5).

       dc240
         Supports the Kodak DC240 Digital Camera. See dc240(5).

       dc25
         Supports Kodak DC20/DC25 Digital Cameras. See dc25(5).

       dmc
         Supports the Polaroid Digital Microscope Camera. See dmc(5).

       gphoto2
         Supports  digital  cameras  supported  by the gphoto2 library package.
         (See http://www.gphoto.org for more information and  a  list  of  sup-
         ported  cameras.)   Gphoto2 supports over 140 different camera models.
         However, please note that more development and testing is  needed  be-
         fore  all  of  these  cameras  will be supported by SANE backend.  See
         gphoto2(5).

       qcam
         Supports Connectix QuickCam cameras. See qcam(5).

       stv680
         Supports webcams with a stv680 chip. See stv680(5) for details.

       Also,   have   a   look   at   the   backend   information    page    at
       http://www.sane-project.org/sane-supported-devices.html  and the list of
       projects in /usr/share/doc/libsane/PROJECTS.

MISCELLANEOUS BACKENDS
       dll
         Implements a SANE backend that provides access to an arbitrary  number
         of other SANE backends by dynamic loading. See sane-dll(5).

       net
         The  SANE  network daemon saned(8) provides access to scanners located
         on different computers in connection with the sane-net(5) backend. See
         saned(8).

       pnm
         PNM image reader pseudo-backend. The purpose of this backend  is  pri-
         marily to aid in debugging of SANE frontends. See sane-pnm(5).

       pint
         Supports scanners that use the PINT (Pint Is Not Twain) device driver.
         The  PINT  driver is being actively developed on the OpenBSD platform,
         and has been ported to a few other *NIX-like  operating  systems.  See
         sane-pint(5).

       test
         Tests  frontends and the SANE installation.  It provides test pictures
         and various test options. See sane-test(5).

       v4l
         Provides generic access to video cameras and similar  equipment  using
         the V4L (Video for Linux) API. See sane-v4l(5).

       Also,    have    a   look   at   the   backend   information   page   at
       http://www.sane-project.org/sane-supported-devices.html and the list  of
       projects in /usr/share/doc/libsane/PROJECTS.

CHANGING THE TOP-LEVEL BACKEND
       By  default,  all  SANE backends (drivers) are loaded dynamically by the
       sane-dll meta backend. If you have any questions about the dynamic load-
       ing, read sane-dll(5).  SANE frontends can also be linked to other back-
       ends  directly  by  copying  or  linking  a  backend  to  libsane.so  in
       /usr/lib/x86_64-linux-gnu/sane.

DEVELOPER'S DOCUMENTATION
       It's  not  hard to write a SANE backend. It can take some time, however.
       You should have basic knowledge of C and enough patience to work through
       the documentation and find out how your scanner  works.  Appended  is  a
       list of some documents that help to write backends and frontends.

       The  SANE  standard  defines the application programming interface (API)
       that is used to communicate between frontends and backends.  It  can  be
       found at http://sane-project.gitlab.io/standard/ .

       There  is  some  more information for programmers in /usr/share/doc/lib-
       sane/backend-writing.txt.  Most of the internal  SANE  routines  (sanei)
       are  documented  using doxygen: http://www.sane-project.org/sanei/.  Be-
       fore a new backend or frontend  project  is  started,  have  a  look  at
       /usr/share/doc/libsane/PROJECTS for projects that are planned or not yet
       included  into  the  SANE  distribution  and at our bug-tracking system:
       http://www.http://www.sane-project.org/bugs.html.

       There are some links on how to find out about the protocol of a scanner:
       http://www.meier-geinitz.de/sane/misc/develop.html.

       If you start writing a backend or frontend or any other  part  of  SANE,
       please contact the sane-devel mailing list for coordination so that work
       is not duplicated.

FILES
       /etc/sane.d/*.conf
              The backend configuration files.

       /usr/lib/x86_64-linux-gnu/sane/libsane-*.a
              The static libraries implementing the backends.

       /usr/lib/x86_64-linux-gnu/sane/libsane-*.so
              The  shared  libraries implementing the backends (present on sys-
              tems that support dynamic loading).

       /usr/share/doc/libsane/*
              SANE documentation: The READMEs, text files for backends etc.

PROBLEMS
       If your device isn't found but you know that it is supported, make  sure
       that it is detected by your operating system. For SCSI and USB scanners,
       use the sane-find-scanner(1) utility.  It prints one line for each scan-
       ner  it  has  detected  and  some comments (#).  If sane-find-scanner(1)
       finds your scanner only as root but not as normal user, the  permissions
       for  the  device  files are not adjusted correctly. If the scanner isn't
       found at all, the operating system hasn't detected it and may need  some
       help.  Depending  on  the  type  of  your  scanner,  read sane-usb(5) or
       sane-scsi(5).  If your scanner (or other device) is not  connected  over
       the  SCSI  bus or USB, read the backend's manual page for details on how
       to set it up.

       Is your scanner detected by the operating system but not by  SANE?   Try
       scanimage -L.   If  the  scanner  is not found, check that the backend's
       name is mentioned in /etc/sane.d/dll.conf.  Some backends are  commented
       out  by  default. Remove the comment sign for your backend in this case.
       Also some backends aren't compiled at all if one of their  prerequisites
       are  missing.  Examples include dc210, dc240, canon_pp, hpsj5s, gphoto2,
       pint, qcam, v4l, net, sm3600, snapscan, pnm. If you need  one  of  these
       backends  and  it  isn't  available,  read the build instructions in the
       README file and the individual manual pages of the backends.

       Another reason for not being detected by scanimage -L may be  a  missing
       or  incorrect  configuration  in the backend's configuration file. While
       SANE tries to automatically find most scanners, some can't be setup cor-
       rectly without the intervention of the administrator. Also on some oper-
       ating systems auto-detection may not work. Check  the  backend's  manual
       page for details.

       If  your scanner is still not found, try setting the various environment
       variables that are available to assist in  debugging.   The  environment
       variables  are documented in the relevant manual pages.  For example, to
       get the maximum amount of debug information when testing a  Mustek  SCSI
       scanner,  set  environment  variables SANE_DEBUG_DLL, SANE_DEBUG_MUSTEK,
       and SANE_DEBUG_SANEI_SCSI to 128  and  then  invoke  scanimage -L.   The
       SANE_DEBUG_DLL messages tell if the sane-mustek(5) backend was found and
       loaded  at  all. The SANE_DEBUG_MUSTEK messages explain what the backend
       is doing while the SANE_DEBUG_SCSI debugging shows the  low  level  han-
       dling.  If  you  can't find out what's going on by checking the messages
       carefully, contact the sane-devel mailing list for help  (see  REPORTING
       BUGS below).

       Now  that your scanner is found by scanimage -L, try to do a scan: scan-
       image >image.pnm.  This command starts a scan for  the  default  scanner
       with  default  settings. All the available options are listed by running
       scanimage --help.  If scanning aborts with an error message, turn on de-
       bugging as mentioned above. Maybe the configuration file needs some tun-
       ing, e.g. to setup the path to a firmware that is needed by  some  scan-
       ners.  See  the backend's manual page for details. If you can't find out
       what's wrong, contact sane-devel.

       To check that the SANE libraries are installed correctly you can use the
       test backend, even if you don't have a scanner or other SANE device:

              scanimage -d test -T

       You should get a list of PASSed tests. You can do  the  same  with  your
       backend by changing "test" to your backend's name.

       So  now scanning with scanimage (1) works and you want to use one of the
       graphical frontends like xsane(1), xscanimage(1), or quiteinsane(1)  but
       those  frontends  don't  detect your scanner? One reason may be that you
       installed two versions of SANE.  E.g. the version that was installed  by
       your  distribution in /usr and one you installed from source in /usr/lo-
       cal/.  Make sure that only one version is  installed.  Another  possible
       reason  is,  that  your  system's dynamic loader can't find the SANE li-
       braries. For Linux, make sure  that  /etc/ld.so.conf  contains  /usr/lo-
       cal/lib and does not contain /usr/local/lib/sane.  See also the documen-
       tation of the frontends.

HOW CAN YOU HELP SANE
       We  appreciate  any  help we can get. Please have a look at our web page
       about contributing to SANE: http://www.sane-project.org/contrib.html

CONTACT
       For reporting bugs or requesting new features, please use our bug-track-
       ing system: http://www.sane-project.org/bugs.html.  You can also contact
       the author of your backend directly. Usually the email  address  can  be
       found  in  the /usr/share/doc/libsane/AUTHORS file or the backend's man-
       page. For general discussion about SANE, please  use  the  SANE  mailing
       list  sane-devel (see http://www.sane-project.org/mailing-lists.html for
       details).

SEE ALSO
       saned(8), sane-find-scanner(1), scanimage(1),  sane-abaton(5),  sane-ag-
       fafocus(5),    sane-apple(5),   sane-artec(5),   sane-artec_eplus48u(5),
       sane-as6e(5),      sane-avision(5),      sane-bh(5),      sane-canon(5),
       sane-canon630u(5), sane-canon_dr(5), sane-canon_pp(5), sane-cardscan(5),
       sane-coolscan(5),  sane-coolscan2(5),  sane-coolscan3(5), sane-dc210(5),
       sane-dc240(5), sane-dc25(5),  sane-dll(5),  sane-dmc(5),  sane-epson(5),
       sane-epson2(5),    sane-escl(5),    sane-fujitsu(5),    sane-genesys(5),
       sane-gphoto2(5),     sane-gt68xx(5),     sane-hp(5),     sane-hpsj5s(5),
       sane-hp3500(5),    sane-hp3900(5),    sane-hp4200(5),    sane-hp5400(5),
       sane-hpljm1005(5), sane-ibm(5),  sane-kodak(5),  sane-leo(5),  sane-lex-
       mark(5),   sane-lexmark_x2600(5),   sane-ma1509(5),  sane-matsushita(5),
       sane-microtek2(5), sane-microtek(5), sane-mustek(5),  sane-mustek_pp(5),
       sane-mustek_usb(5),   sane-mustek_usb2(5),   sane-nec(5),   sane-net(5),
       sane-niash(5), sane-pie(5),  sane-pint(5),  sane-plustek(5),  sane-plus-
       tek_pp(5),  sane-pnm(5),  sane-qcam(5),  sane-ricoh(5),  sane-ricoh2(5),
       sane-s9036(5),     sane-sceptre(5),     sane-scsi(5),     sane-sharp(5),
       sane-sm3600(5),    sane-sm3840(5),    sane-snapscan(5),   sane-sp15c(5),
       sane-st400(5),    sane-stv680(5),    sane-tamarack(5),    sane-teco1(5),
       sane-teco2(5),       sane-teco3(5),      sane-test(5),      sane-u12(5),
       sane-umax1220u(5),    sane-umax(5),    sane-umax_pp(5),     sane-usb(5),
       sane-v4l(5), sane-xerox_mfp(5)

AUTHOR
       David  Mosberger-Tang and many many more (see /usr/share/doc/libsane/AU-
       THORS for details).  This man page was written by Henning Meier-Geinitz.
       Quite a lot of text was taken from the SANE standard, several man pages,