dwww Home | Manual pages | Find package

sane-avision(5)           SANE Scanner Access Now Easy          sane-avision(5)

NAME
       sane-avision - SANE backend for Avision branded and Avision OEM (HP, Mi-
       nolta, Mitsubishi, UMAX and possibly more) flatbed and film scanners.

DESCRIPTION
       The  sane-avision  library  implements  a SANE (Scanner Access Now Easy)
       backend that provides access to various Avision scanners and the Avision
       OEM scanners labelled by HP, Minolta, Mitsubishi or Fujitsu.

       It is fully big-endian aware and in everyday use on  PowerPC  and  SPARC
       systems.

       I suggest you hold one hand on the power-button of the scanner while you
       try the first scans - especially with film-scanners!

CONFIGURATION
       The  configuration  file  for  this  backend resides in /etc/sane.d/avi-
       sion.conf.

       Its contents is a list of device names that correspond  to  Avision  and
       Avision  compatible  scanners and backend-options. Empty lines and lines
       starting with a hash mark (#) are ignored. A sample  configuration  file
       is shown below:

        # this is a comment
        option force-a4
        option force-a3
        option skip-adf
        option disable-gamma-table
        option disable-calibration
        #scsi Vendor Model Type Bus Channel ID LUN
        scsi AVISION
        scsi HP
        scsi /dev/scanner
        usb 0x03f0 0x0701

       force-a4:
              Forces the backend to overwrite the scanable area returned by the
              scanner  to  ISO  A4. Scanner that are known to return bogus data
              are marked in the backend so if you need this option  please  re-
              port this to the backend maintainer. USE WITH CARE!

       force-a3:
              Forces the backend to overwrite the scanable area returned by the
              scanner  to  ISO  A3. Scanner that are known to return bogus data
              are marked in the backend so if you need this option  please  re-
              port this to the backend maintainer. USE WITH CARE!

       skip-adf:
              Forces  the backend to ignore an inconsistent ADF status returned
              by the scanner (ADF not present, but ADF model number  non-zero).
              Without  this  option,  the backend will make several attempts to
              reset the ADF and retry the query in  this  situation,  and  will
              fail  with  a  "not supported" error if the ADF still doesn't re-
              spond.

       disable-gamma-table:
              Disables the usage of the scanner's gamma-table.  You  might  try
              this if your scans hang or only produce random garbage.

       disable-calibration:
              Disables  the  scanner's color calibration. You might try this if
              your scans hang or only produce random garbage.

       Note:  Any option above modifies the default code-flow for your scanner.
              The options should only be used when you encounter problems  with
              the  default  behavior  of the backend. Please report the need of
              options to the backend-author so the backend can be fixed as soon
              as possible.

DEVICE NAMES
       This backend expects device names of the form:

              scsi scsi-spec

              usb usb-spec

       Where scsi-spec is the path-name to a special device or a device ID  for
       the  device  that corresponds to a SCSI scanner. The special device name
       must be a generic SCSI device or a symlink to such a device, for example
       on Linux /dev/sga or /dev/sg0.  The device ID is the ID returned by  the
       scanner, for example "HP" or "AVISION". See sane-scsi(5) for details.

       Note:  Since the backend now includes native USB access, it is no longer
              needed - even considered obsolete - to access USB scanner via the
              SCSI emulation (named hpusbscsi on Linux) for Avision USB devices
              such as the HP 53xx, HP 74xx or Minolta film-scanners.

       usb-spec  is the USB device name, the vendor/product ID pair or the name
       used by libusb corresponding to the USB  scanner.  For  example  "0x03f0
       0x0701" or "libusb:002:003". See sane-usb(5) for details.

       The  program  sane-find-scanner(1) helps to find out the correct scsi or
       usb device name.

       A list with supported devices is built into the avision backend so  nor-
       mally specifying an ID should not be necessary.

FILES
       /etc/sane.d/avision.conf
              The backend configuration file (see also description of SANE_CON-
              FIG_DIR below).

       /usr/lib/x86_64-linux-gnu/sane/libsane-avision.a
              The static library implementing this backend.

       /usr/lib/x86_64-linux-gnu/sane/libsane-avision.so
              The  shared library implementing this backend (present on systems
              that support dynamic loading).

ENVIRONMENT
       SANE_CONFIG_DIR
              This environment variable specifies the list of directories  that
              may  contain the configuration file.  On *NIX systems, the direc-
              tories are separated by a colon (`:'), under OS/2, they are sepa-
              rated by a semi-colon (`;').  If this variable is  not  set,  the
              configuration file is searched in two default directories: first,
              the  current working directory (".") and then in /etc/sane.d.  If
              the value of the environment variable  ends  with  the  directory
              separator  character,  then  the default directories are searched
              after the explicitly specified directories.  For example, setting
              SANE_CONFIG_DIR to "/tmp/config:"  would  result  in  directories
              tmp/config, ., and /etc/sane.d being searched (in this order).

       SANE_DEBUG_AVISION
              If  the library was compiled with debug support enabled, this en-
              vironment variable controls the debug  level  for  this  backend.
              Higher debug levels increase the verbosity of the output. The de-
              bug  level  7  is  the  author's preferred value to debug backend
              problems.

              Example: export SANE_DEBUG_AVISION=7

SEE ALSO
       sane(7), sane-scsi(5), sane-usb(5)
       http://exactcode.com/site/open_source/saneavision

MAINTAINER
       René Rebe

AUTHOR
       René Rebe and Meino Christian Cramer

                                  11 Jul 2008                   sane-avision(5)

Generated by dwww version 1.16 on Sat Oct 3 08:36:01 CEST 2026.