dwww Home | Manual pages | Find package

sane-coolscan2(5)         SANE Scanner Access Now Easy        sane-coolscan2(5)

NAME
       sane-coolscan2 - SANE backend for Nikon Coolscan film scanners

DESCRIPTION
       The  sane-coolscan2  library implements a SANE (Scanner Access Now Easy)
       backend that provides access to  Nikon  Coolscan  film  scanners.   Some
       functions  of  this  backend should be considered beta-quality software.
       Most functions have been stable for a long time, but of course  new  de-
       velopment  can  not  and  will not function properly from the very first
       day. Please report any strange behaviour to the maintainer of the  back-
       end.

       At present, the following scanners are known to work with this backend:

              Model:                       Connection Type
              ---------------------------  -------------------
              LS-30 (Coolscan III)         SCSI
              LS-2000                      SCSI
              LS-40 ED (Coolscan IV)       USB
              LS-4000 ED                   IEEE 1394
              LS-8000 ED                   IEEE 1394

       Please send mail to the backend author (andras@users.sourceforge.net) to
       report successes or failures.

OPTIONS
       The  options the backend supports can either be selected through command
       line options to programs like scanimage(1) or through  GUI  elements  in
       xscanimage(1) or xsane(1).

       Valid command line options and their syntax can be listed by using:

              scanimage --help -d coolscan2:<interface>:<device>

       where <interface> and <device> specify the device in question, as in the
       configuration file (see next section). The -d parameter and its argument
       can  be  omitted  to obtain information on the first scanner identified.
       Use the command:

              scanimage -L

       to list all devices recognized by your SANE installation.

       The options should be fully described by  the  description  or  tooltips
       given  by  frontend. Here is a description of some of the most important
       options, in the syntax with which they must be supplied to scanimage(1):

       --frame <n>
              This option specifies which frame to operate on, if  a  motorized
              film  strip  feeder or APS adapter are used. The frame number <n>
              ranges from 1 to the number of frames available, which is  sensed
              each time the backend is initialized (usually each time you start
              the frontend).

       --subframe <x>
              This  option  shifts the scan window by the specified amount (de-
              fault unit is mm).

       --infrared=yes/no
              If set to "yes", the scanner will read the infrared channel, thus
              allowing defect removal in software. The infrared image  is  read
              during  a  second scan, with no options altered. The backend must
              not be restarted between the scans.   If  you  use  scanimage(1),
              perform a batch scan with --batch-count=2 to obtain the IR infor-
              mation.

       --depth <n>
              Here  <n> can either be 8 or the maximum number of bits supported
              by the scanner (10, 12, or 14). It specifies whether or  not  the
              scanner  reduces  the scanned data to 8 bits before sending it to
              the backend. If 8 bits are used, some information and thus  image
              quality  is  lost,  but the amount of data is smaller compared to
              higher depths. Also, many imaging programs and image formats can-
              not handle depths greater than 8 bits.

       --autofocus
              Perform autofocus operation. Unless otherwise  specified  by  the
              other  options ( --focus-on-centre and friends), focusing is per-
              formed on the centre of the selected scan area.

       --ae-wb

       --ae   Perform a pre-scan to calculate  exposure  values  automatically.
              --ae-wb  will  maintain the white balance, while --ae will adjust
              each channel separately.

       --exposure
              Multiply all exposure times with this value. This allows exposure
              correction without modifying white balance.

       --load Load the next slide when using the slide loader (applies only  to
              the SF-200 bulk feeder).

       --eject
              Eject  the  film  strip  or  mounted  slide  when using the slide
              loader.

       --reset
              Reset scanner. The scanner will perform the same action  as  when
              power is turned on: it will eject the slide (with the SF-200 bulk
              feeder)  and  calibrate itself. Use this whenever the scanner re-
              fuses to load a slide properly, as a result of which --eject does
              not work.

CONFIGURATION FILE
       The configuration  file  /etc/sane.d/coolscan2.conf  specifies  the  de-
       vice(s)  that the backend will use. Owing to the nature of the supported
       connection types SCSI, USB, and IEEE  1394,  the  default  configuration
       file  supplied  with  the  SANE  distribution  should work without being
       edited.

       Each line in the configuration file is either of  the  following,  where
       all entries are case-sensitive:

       blank or starting with a '#' character
              These  lines  are  ignored,  thus '#' can be used to include com-
              ments.

       containing only the word "auto"
              This instructs the backend to probe for a scanner by scanning the
              buses for devices with known identifiers. This is the default ac-
              tion when no configuration file is present.

       a line of the form <interface>:<device>
              Here <interface> can be one of "scsi" or "usb", and  <device>  is
              the  device  file of the scanner. Note that IEEE 1394 devices are
              handled by the SBP-2 module in the kernel and appear to  SANE  as
              SCSI devices.

FILES
       /usr/lib/x86_64-linux-gnu/sane/libsane-coolscan2.a
              The static library implementing this backend.

       /usr/lib/x86_64-linux-gnu/sane/libsane-coolscan2.so
              The  shared library implementing this backend (present on systems
              that support dynamic loading).

       /etc/sane.d/coolscan2.conf
              Configuration file for this backend, read each time  the  backend
              is initialized.

ENVIRONMENT
       SANE_DEBUG_COOLSCAN2
              If  the library was compiled with debug support enabled, this en-
              vironment variable controls the debug  level  for  this  backend.
              E.g.,  a  value  of  128 requests all debug output to be printed.
              Smaller levels reduce verbosity.

SEE ALSO
       sane-scsi(5), sane-usb(5), scanimage(1), xscanimage(1), xsane(1)

BUGS
       Currently, the SANE protocol does not allow automatically  updating  op-
       tions  whenever the hardware changes. Thus the number of choices for the
       --frame option will be fixed when the backend  is  initialized  (usually
       when  the  user  runs  the frontend). In particular, if there is no film
       strip in the automatic film strip feeder when the  backend  is  initial-
       ized,  the  --frame  option will not appear at all. Also, restarting the
       frontend after swapping film adapters is strongly recommended.

       Linux kernels prior to 2.4.19 had a patch that  truncated  INQUIRY  data
       from  IEEE 1394 scanners to 36 bytes, discarding vital information about
       the scanner. The IEEE 1394 models therefore only  work  with  2.4.19  or
       later.

       No  real  bugs  currently  known, please report any to the backend main-
       tainer or the SANE developers' email list.

AUTHORS
       The  backend  is  written  and   maintained   by   AndrĂ¡s   Major   <an-
       dras@users.sourceforge.net>.

                                  11 Jul 2008                 sane-coolscan2(5)

Generated by dwww version 1.16 on Sat Oct 3 06:25:56 CEST 2026.