NAME
       sane-epson2 - SANE backend for EPSON scanners

DESCRIPTION
       The  sane-epson2  library  implements  a  SANE (Scanner Access Now Easy)
       backend that provides access to Epson flatbed  scanners.   This  library
       supports  a similar set of scanners as the sane-epson driver but was de-
       veloped to support a wider range of connections to the scanner;  include
       network access.

       Because  sane-epson and sane-epson2 drivers support many of the same de-
       vices, if one driver gives you problems you may try disabling it to  try
       the  other.   This  can  be  done  by  removing the driver name from the
       dll.conf or perhaps by commenting out the options in epson.conf  or  ep-
       son2.conf.

       At present, the following scanners are known to work with this backend:

              Model:                       Connection Type
              ---------------------------  -------------------
              ActionScanner II             SCSI, parallel
              AcuLaser CX11 Series         USB, Network
              AcuLaser CX21 Series         USB, Network
              CX-3200                      USB
              CX-3600                      USB
              CX-3650                      USB
              CX-4050                      USB
              CX-4600                      USB
              CX-4800                      USB
              CX-5000                      USB
              CX-5200                      USB
              CX-5400                      USB
              CX-6300                      USB
              CX-6400                      USB
              CX-6500                      USB
              CX-6600                      USB
              DX-3800                      USB
              DX-5000                      USB
              DX-5050                      USB
              DX-6000                      USB
              DX-7400                      USB
              ES-300C                      SCSI, parallel
              ES-300GS                     SCSI
              ES-600C                      parallel
              ES-1200C                     parallel
              Expression 636               SCSI
              Expression 800               SCSI
              Expression 1600              USB, SCSI, IEEE-1394
              Expression 1680              USB, SCSI, IEEE-1394
              FilmScan 200                 SCSI
              GT-5000                      SCSI, parallel
              GT-5500                      SCSI
              GT-6000                      parallel
              GT-6500                      parallel
              GT-7000                      SCSI
              GT-8000                      SCSI
              GT-8500                      SCSI
              Perfection 610               USB
              Perfection 636S              SCSI
              Perfection 636U              USB
              Perfection 640               USB
              Perfection 1200S             SCSI
              Perfection 1200U             USB
              Perfection 1240              USB, SCSI
              Perfection 1640              USB, SCSI
              Perfection 1650              USB
              Perfection 1660              USB
              Perfection 2400              USB
              Perfection 2450              USB, IEEE-1394
              Perfection 3200              USB
              Perfection 4870              USB
              Perfection 4990              USB
              RX-425                       USB
              RX-500                       USB
              RX-600                       USB
              RX-700                       USB
              V700                         USB, IEEE-1394
              V750                         USB, IEEE-1394
              and many more. The official list is on the Sane web site.

       For  other scanners the software  may or may not work.  Please send mail
       to the sane-backend mailing list to report success with scanners not  on
       the list or problems with scanners that are listed.

OPTIONS
       The  options the backend supports can either be selected through command
       line options to programs like scanimage(1) or through  GUI  elements  in
       programs like xscanimage(1) or xsane(1).

       Valid command line options and their syntax can be listed by using

              scanimage --help -d epson2

       Not all devices support all options.

       Scan Mode
              The  --mode  switch  selects  the  basic mode of operation of the
              scanner. Valid choices are Binary, Gray and  Color.   The  Binary
              mode  is  black  and  white only, Gray will produce 256 levels of
              gray or more depending on the scanner  and  Color  means  24  bit
              color  mode or more depending on the scanner.  Some scanners will
              internally use 36 bit color, their external interface however may
              only support 24 bits.

              The --depth option selects the bit depth the  scanner  is  using.
              This option is only available for scanners that support more than
              one  bit  depth. Older scanners will always transfer the image in
              8bit mode. Newer scanners allow one to select either 8  bits,  12
              or  14 bits per color channel. For a color scan this means an ef-
              fective color depth of 36 or 42 bits over all three channels. The
              valid choices depend on the scanner model.

              The --halftoning switch selects the mode that is used  in  Binary
              mode.  Valid  options  are  "None",  "Halftone  A  (Hard  Tone)",
              "Halftone B (Soft Tone)", "Halftone C (Net  Screen)",  "Dither  A
              (4x4  Bayer)",  "Dither  B  (4x4  Spiral)",  "Dither  C  (4x4 Net
              Screen)", "Dither D (8x4 Net Screen)",  "Text  Enhanced  Technol-
              ogy", "Download pattern A", and "Download pattern B".

              The  --dropout  switch selects the so called dropout color. Valid
              options are None, Red, Green and Blue. The default is  None.  The
              dropout  color  is  used  for monochrome scanning and selects the
              color that is not scanned. This can be used to e.g. scan an orig-
              inal with a colored background.

              The --brightness switch controls  the  brightness  of  the  scan.
              Valid  options are integer values from -3 to 3. The default is 0.
              The larger the brightness value, the brighter the image gets.  If
              a  user  defined  table for the gamma correction is selected, the
              brightness parameter is not available.

              The --sharpness switch sets the  sharpness  of  the  image  data.
              Valid  options  are  integer values from -2 to 2, with -2 meaning
              "Defocus",  -1  "Defocus  slightly",  0  "Normal",   1   "Sharpen
              slightly" and 2 "Sharpen".

              The  --gamma-correction  switch  controls  the scanner's internal
              gamma correction. Valid options are  "Default",  "User  defined",
              "High density printing" "Low density printing" and "High contrast
              printing".

              The  --color-correction  switch  controls  the scanner's internal
              color correction function. Valid  options  are  "No  Correction",
              "Impact-dot printers", "Thermal printers", "Ink-jet printers" and
              "CRT monitors". The default is "CRT monitors".

              The  --resolution  switch selects the resolution for a scan. Some
              EPSON scanners will scan in any resolution between the lowest and
              highest possible value. The list reported by the scanner  can  be
              displayed using the "--help -d epson" parameters to scanimage(1).

              The  --threshold  switch  selects the minimum brightness to get a
              white point.

              The --mirror option controls the way the  image  is  scanned.  By
              reading  the image data from right to left the image is mirrored.
              Valid options are "yes" and "no". The default is "no".

              The --auto-area-segmentation switch activates the automatic  area
              segmentation for monochrome scans. The scanner will try to deter-
              mine which areas are text and which contain images. The image ar-
              eas  will  be halftoned, and the text will be improved. Valid op-
              tions are "yes" and "no". The default is "yes".

              The --red-gamma-table parameter can be used to  download  a  user
              defined  gamma  table  for the red channel. The valid options are
              the same as for --gamma-table.

              The --green-gamma-table parameter can be used to download a  user
              defined  gamma table for the green channel. The valid options are
              the same as for --gamma-table.

              The --blue-gamma-table parameter can be used to download  a  user
              defined  gamma  table for the blue channel. The valid options are
              the same as for --gamma-table.

              The --wait-for-button parameter can be used  to  wait  until  the
              button  on  the  scanner  is  pressed  to actually start the scan
              process.

              The color correction coefficients  --cct-1  --cct-2  --cct-3  ...
              --cct-9  will  install color correction coefficients for the user
              defined color correction. Values are specified as integers in the
              range -127..127.

              The --preview option requests a preview scan. The frontend  soft-
              ware  automatically  selects  a low resolution. Valid options are
              "yes" and "no". The default is "no".

              The geometry options -l -t -x -y control the scan area:  -l  sets
              the  top  left x coordinate, -t the top left y coordinate, -x se-
              lects the width and -y the height of the scan area.  All  parame-
              ters are specified in millimeters.

              The --source option selects the scan source. Valid options depend
              on the installed options. The default is "Flatbed".

              The --auto-eject option will eject a page after scanning from the
              document feeder.

              The  --film-type  option will select the film type for scans with
              the transparency unit. This option is only activated if  the  TPU
              is selected as scan source. Valid options are "Negative Film" and
              "Positive Film".

              The  --focus-position  option  selects the focus position for all
              scans. Valid options are "Focus 2.5mm above glass" and "Focus  on
              glass". The focus on the 2.5mm point above the glass is necessary
              for scans with the transparency unit, so that the scanner can fo-
              cus  on the film if one of the film holders is used.  This option
              is only functional for selected scanners, all other scanners will
              ignore this option.

              The --bay option selects which bay to scan.

              The --eject option ejects the sheet in the ADF.

              The --adf-mode option select the ADF mode (simplex/duplex).

CONFIGURATION FILE
       The configuration file /etc/sane.d/epson2.conf specifies  the  device(s)
       that the backend will use. Possible connection types are:

       SCSI   This is the default, and if nothing else is specified the backend
              software  will open a given path as SCSI device. More information
              about valid syntax for SCSI devices can be found in sane-scsi(5).
              Usually SCSI scanners are configured with a line "scsi EPSON"  in
              this  file.  In  some  cases  it may be necessary to only use the
              string "scsi" (e.g. for the GT-6500).

       PIO - Parallel Interface
              The parallel interface can be configured in two ways: An  integer
              value  starting at the beginning of a line will be interpreted as
              the IO address of the parallel port. To make it  clearer  that  a
              configured  IO address is a parallel port the port address can be
              preceded by the string "PIO". The PIO connection does not  use  a
              special  device file in the /dev directory. The IO address can be
              specified in hex mode (prefixed with "0x").

       USB    For USB scanners not automatically detect, their VENDOR and PROD-
              UCT ID can be specified manually in the config file.  More infor-
              mation about valid  syntax  for  USB  devices  can  be  found  in
              sane-usb(5).

       Network
              Network scanners can be auto-discovered if autodiscovery is spec-
              ified after net keyword.  An IP address to connect to can also be
              used.

FILES
       /usr/lib/x86_64-linux-gnu/sane/libsane-epson2.a
              The static library implementing this backend.

       /usr/lib/x86_64-linux-gnu/sane/libsane-epson2.so
              The  shared library implementing this backend (present on systems
              that support dynamic loading).

ENVIRONMENT
       SANE_DEBUG_EPSON2
              If the library was compiled with debug support enabled, this  en-
              vironment  variable  controls  the  debug level for this backend.
              E.g., a value of 128 requests all debug  output  to  be  printed.
              Smaller levels reduce verbosity.

       SANE_DEBUG_EPSON2_SCSI
              If  the library was compiled with debug support enabled, this en-
              vironment variable controls the SCSI related debug level for this
              backend.  Only a value of 2 is supported.

       SANE_DEBUG_EPSON2_NET
              If the library was compiled with debug support enabled, this  en-
              vironment  variable  controls the network related debug level for
              this backend.  E.g., a value of 128 requests all debug output  to
              be printed.  Smaller levels reduce verbosity.

       SANE_EPSON2_CMD_LVL
              This  allows  one  to override the function or command level that
              the backend uses to communicate with the  scanner.  The  function
              level  a scanner supports is determined during the initialization
              of the device. If the backend does  not  recognize  the  function
              level  reported  by the scanner it will default to function level
              B3. Valid function levels are A1, A2, B1, B2, B3, B4, B5, B6, B7,
              B8, D1 and F5. Use this feature only if you know what you are do-
              ing!

SEE ALSO
       sane-scsi(5), sane-usb(5), scanimage(1), xscanimage(1), xsane(1)

BUGS
       None :-) At least none are currently known.

UNSUPPORTED DEVICES
       The backend may be used with Epson scanners that are not yet listed  un-
       der  the list of supported devices. A scanner that is not recognized may
       default to the function level B3, which means  that  not  all  functions
       that the scanner may be capable of are accessible.

       If the scanner is not even recognized as an Epson scanner this is proba-
       bly  because  the device name reported by the scanner is not in the cor-
       rect format. Please send this  information  to  the  backend  maintainer
       (email  address  is in the AUTHOR section of this man page or in the AU-
       THORS file of the SANE distribution).

AUTHOR
       The package is written by Alessandro Zummo and is based on previous work
       done by Karl Hienz Kremer in the epson package as well as based on  work
       by Christian Bucher and Kazuhiro Sasayama.