dwww Home | Manual pages | Find package

sane-genesys(5)           SANE Scanner Access Now Easy          sane-genesys(5)

NAME
       sane-genesys  -  SANE  backend  for GL646, GL841, GL843, GL847 and GL124
       based USB flatbed scanners

DESCRIPTION
       The sane-genesys library implements a SANE  (Scanner  Access  Now  Easy)
       backend  that  provides  access  to  USB  flatbed  scanners based on the
       Genesys GL646, GL841, GL843, GL847 and GL124  chips.   At  present,  the
       following scanners are known to work with this backend:

              Canon LiDE 35/40/50/60/100/110/120/200/210/220/700
              Hewlett-Packard HP2300C/HP2400/HP3670/HP3690/G4010/G4050
              Medion MD5345/MD6228/MD6274
              Panasonic KV-SS080
              Plustek OpticBook 3600
              Pentax DSmobile 600
              Syscan/Ambir DocketPORT 467/485/487/665/685
              Visioneer  OneTouch 7100/Strobe XP100 (rev3)/XP200/XP300/Roadwar-
              rior
              Xerox Travel Scanner 100, OneTouch 2400

       This is stable software for supported models. But if  you  test  new  or
       untested  scanners,  keep your hand at the scanner's plug and unplug it,
       if the head bumps at the end of the scan area.

       If you own a scanner other than the ones listed above  that  works  with
       this  backend,  please  let  me know this by sending the scanner's exact
       model  name  and  the   USB   vendor   and   device   ids   (e.g.   from
       /proc/bus/usb/devices,  sane-find-scanner  or  syslog) to the sane-devel
       mailing list. Even if the scanner's name is only slightly different from
       the models mentioned above, please let me know.

       If you own a scanner that isn't detected by the genesys backend but  has
       a  GL646, GL841, GL843, GL847 or GL124 chipset, you can try to add it to
       the backend.

CALIBRATION
       To give correct image quality, sheet fed scanners need to be  calibrated
       using  the  calibration  sheet sold with the scanner. To do calibration,
       you must insert this target in the feeder then start calibration  either
       by  passing the --calibrate option to scanimage(1) or by clicking on the
       available 'calibrate' button in the 'advanced options'  in  a  graphical
       frontend.  The result of the calibration is stored in a file in the home
       directory of the user doing it.  If you plug the scanner in another  ma-
       chine  or  use  it with another account, calibration will have to be re-
       done, unless you use the --calibration-file option.  If no  home  direc-
       tory  is  defined,  USERAPPPROFILE will be used, then TMPDIR or TMP.  If
       none of these directories exist, the backend will try to  write  in  the
       current  working  directory. Flatbed scanners also make use of the cali-
       bration file as a cache to avoid calibration before each scan.  Calibra-
       tion  file  name is the name of the scanner model if only one scanner is
       detected. In the case of several identical model, the file name will  be
       the name of the logical USB device name. The expiration time manages the
       time  a  calibration  is valid in cache.  A value of -1 means forever, 0
       means no cache.

EXTRAS SCAN OPTIONS
       --lamp-off-time number
              The lamp will be turned off after the given time (in minutes).  A
              value of 0 means that the lamp won't be turned off.

       --threshold percent
              0..100% (in steps of 1). Select minimum brightness to get a white
              point. Pixels with brightness below that value will be scanned as
              black.

       --brightness value
              -100..100  (in steps of 1). Set the brightness enhancement. 0 for
              no enhancement, negative values to decrease brightness, and posi-
              tive values to increase it.

       --contrast value
              -100..100 (in steps of 1). Set the contrast enhancement. 0 for no
              enhancement, negative values to decrease contrast,  and  positive
              values to increase it.

       --disable-interpolation yes|no
              When  using  high  resolutions where the horizontal resolution is
              smaller than vertical resolution, data is expanded by software to
              preserve picture geometry. This can be disabled by this option to
              get real scanned data.

       --disable-dynamic-lineart yes|no
              Disable use of a software adaptive algorithm to generate  lineart
              and rely on hardware lineart.

       --color-filter None|Red|Green|Blue
              When  using  gray  or lineart this option selects the used color.
              Using a color filter will give a monochrome scan. CIS based scan-
              ners can do true gray when no filter (None value) is selected.

       --lamp-off-scan
              The lamp will be turned off during the scan. Calibration is still
              done with lamp on.

       --clear-calibration
              Clear calibration cache data, triggering a  new  calibration  for
              the device when the next scan will happen.

       --calibration-file
              Specify  the calibration file name to use. At least the directory
              containing the file must exist, since it won't be  created.  This
              option  is  disabled if the backend is run as root. It maybe used
              in case of sheet-fed scanners to share  a  calibration  file  for
              several users.

       --expiration-time
              Specify  the time (in minutes) a cached calibration is considered
              valid. If older than the given value, a new calibration is  done.
              A  value of -1 means no expiration and cached value are kept for-
              ever unless cleared by user with the calibration clear option.  A
              value of 0 means cache is disabled.

       Additionally,  several  'software'  options  are exposed by the backend.
       These are reimplementations of  features  provided  natively  by  larger
       scanners,  but  running  on  the host computer. This enables smaller ma-
       chines to have similar capabilities. Please note that these features are
       somewhat simplistic, and may not perform as well as the native implemen-
       tations. Note also that these features all require that the driver cache
       the entire image in memory. This will almost certainly result in  a  re-
       duction of scanning speed.

       --swcrop
              Requests the driver to detect the extremities of the paper within
              the larger image, and crop the empty edges.

       --swdeskew
              Requests  the  driver  to detect the rotation of the paper within
              the larger image, and counter the rotation.

       --swdespeck --despeck X
              Requests the driver to find and remove  dots  of  X  diameter  or
              smaller  from the image, and fill the space with the average sur-
              rounding color.

       --swskip 0..100% (in steps of 1) [0]
              Request driver to discard pages with low numbers of dark pixels.

       --swderotate[=(yes|no)] [no]
              Request driver to detect and correct 90 degree image rotation.

SYSTEM ISSUES
       This backend needs libusb-0.1.6 or later installed, and hasn't tested in
       other configuration than a linux kernel 2.6.9  or  higher.  However,  it
       should  work  any  system with libusb where the SANE package can be com-
       piled. For setting permissions  and  general  USB  information  look  at
       sane-usb(5).

CONFIGURATION
       The  contents of the genesys.conf file is a list of usb lines containing
       vendor and product ids that correspond to USB  scanners.  The  file  can
       also  contain  option lines.  Empty lines and lines starting with a hash
       mark (#) are ignored.  The scanners are autodetected  by  usb  vendor_id
       product_id  statements  which  are  already  included into genesys.conf.
       "vendor_id" and "product_id" are hexadecimal numbers that  identify  the
       scanner.

FILES
       /etc/sane.d/genesys.conf
              The backend configuration file (see also description of SANE_CON-
              FIG_DIR below).

       /usr/lib/x86_64-linux-gnu/sane/libsane-genesys.a
              The static library implementing this backend.

       /usr/lib/x86_64-linux-gnu/sane/libsane-genesys.so
              The  shared library implementing this backend (present on systems
              that support dynamic loading).

ENVIRONMENT
       SANE_CONFIG_DIR
              This environment variable specifies the list of directories  that
              may  contain the configuration file.  On *NIX systems, the direc-
              tories are separated by a colon (`:'), under OS/2, they are sepa-
              rated by a semi-colon (`;').  If this variable is  not  set,  the
              configuration file is searched in two default directories: first,
              the  current working directory (".") and then in /etc/sane.d.  If
              the value of the environment variable  ends  with  the  directory
              separator  character,  then  the default directories are searched
              after the explicitly specified directories.  For example, setting
              SANE_CONFIG_DIR to "/tmp/config:"  would  result  in  directories
              tmp/config, ., and /etc/sane.d being searched (in this order).

       SANE_DEBUG_GENESYS
              If  the library was compiled with debug support enabled, this en-
              vironment variable controls the debug  level  for  this  backend.
              Higher  debug levels increase the verbosity of the output. If the
              debug level is set to 1 or  higher,  some  debug  options  become
              available  that  are normally hidden. Handle them with care. This
              will print messages related to core genesys functions.

       SANE_DEBUG_GENESYS_IMAGE
              If the library was compiled with debug support enabled, this  en-
              vironment variable enables logging of intermediate image data. To
              enable this mode, set the environmental variable to 1.

              Example (full and highly verbose output for gl646):
              export SANE_DEBUG_GENESYS=255

CREDITS
       Jack  McGill  for  donating several sheetfed and flatbed scanners, which
       made possible to add support for them in the genesys backend:
              Hewlett-Packard HP3670
              Visioneer Strobe XP100 (rev3)/XP200/XP300/Roadwarrior
              Canon LiDE 200
              Pentax DSmobile 600
              Syscan/Ambir DocketPORT 467/485/487/665/685
              Xerox Travel Scanner 100, Onetouch 2400

       cncsolutions sponsored and supported the work on the Panasonic KV-SS080.

       Brian Paavo from Benthic Science Limited for donating a Canoscan LiDE
       700F.

       Dany Qumsiyeh for donating a Canoscan LiDE 210 and a LiDE 220.

       Luc Verhaegen for donating a Canoscan LiDE 120.

SEE ALSO
       sane(7), sane-usb(5)

AUTHOR
       Oliver Rauch
       Henning Meier-Geinitz <henning@meier-geinitz.de>
       Gerhard Jaeger <gerhard@gjaeger.de>
       Stéphane Voltz <stef.dev@free.fr>
       Philipp Schmid <philipp8288@web.de>
       Pierre Willenbrock <pierre@pirsoft.dnsalias.org>
       Alexey Osipov <simba@lerlan.ru> for HP2400 final support

LIMITATIONS
       Powersaving isn't implemented for gl646 based scanner. Dynamic (emulated
       from gray data and with dithering) isn't  enabled  for  gl646  scanners.
       Hardware  lineart is limited up to 600 dpi for gl847 based scanners, due
       to the way image sensors are built.

       This backend will be much slower if not using  libusb-1.0.  So  be  sure
       that sane-backends is built with the --enable-libusb_1_0 option.

BUGS
       For  the LiDE 200, the scanned data at 4800 dpi is obtained "as is" from
       sensor.  It seems the windows driver does some digital processing to im-
       prove it, which is not implemented in the backend.

                                   4 Jul 2012                   sane-genesys(5)

Generated by dwww version 1.16 on Sat Oct 3 06:02:12 CEST 2026.