sane-microtek(5)          SANE Scanner Access Now Easy         sane-microtek(5)

NAME
       sane-microtek - SANE backend for Microtek scanners

DESCRIPTION
       The  sane-microtek  library  implements a SANE (Scanner Access Now Easy)
       backend that provides access to the "second generation"  Microtek  scan-
       ners.   At  present,  the  following hardware is known to work with this
       backend:

              Microtek ScanMaker E2, E3, E6
              Microtek ScanMaker II, IIG, IIHR, IISP, III
              Microtek ScanMaker 35t, 35t+, 45t
              Microtek ScanMaker 600GS, 600ZS (see bug notes)
              Agfa StudioScan
              Agfa StudioScan II, StudioScan IIsi
              Agfa Arcus II (but not the "Arcus")
              Agfa DuoScan (preliminary)
              Vobis "Highscreen Realscan"
              Microtek Color PageWiz (preliminary)

              Transparent Media Adapter
              Document AutoFeeder

       The driver supports line art, halftone, 8bpp gray, and 24bpp color scans
       at normal and "expanded" resolutions (i.e. 1200x1200  on  an  E6),  fast
       scans for color previews, and downloadable gamma tables.

       The  supported  scanners  are all SCSI scanners.  However, some parallel
       port models may work (under Linux), if they use  a  parport->scsi  chip,
       and  if  you  can  find a scsi->parport driver.  This is known to be the
       case for the Color PageWiz.

       The driver does not support the newest Microtek scanners,  such  as  the
       V330  and  V660, which use a new and very different SCSI-II command set.
       For those, try the alternate microtek2(5) backend.  Most non-SCSI  scan-
       ners  would use the new command set.  Most scanners newer than the Scan-
       maker E6 would use the new command set.

       If you own a Microtek scanner other than the ones listed above, tell  us
       what happens --- see the BUGS section at the end of this document.

       Although this manual page is generally updated with each release, up-to-
       date information on new releases and extraneous helpful hints are avail-
       able from the backend homepage:

              http://www.mir.com/mtek/

DEVICE NAMES
       This backend expects device names of the form:

              special

       Where  special  is the UNIX path-name for the special device that corre-
       sponds to the scanner.  The special device name must be a  generic  SCSI
       device  or  a symlink to such a device.  Under Linux, such a device name
       could be /dev/sga or /dev/sge, for example.

CONFIGURATION
       The contents of the microtek.conf file is a list of  device  names  that
       correspond  to Microtek scanners.  Empty lines and lines starting with a
       hash mark (#) are ignored.  A sample configuration file is shown below:

              /dev/scanner
              # this is a comment
              /dev/sge

       The configuration file may also contain the special tokens norealcal  or
       noprecal.  norealcal will disable the use of magic, undocumented scanner
       calibration commands which are known to work on the E6, but may not work
       with  other  models.   noprecal  will disable logic which tries to avoid
       scanner precalibration.  This logic would only have  been  activated  if
       the magic calibration code was turned off.

FILES
       /etc/sane.d/microtek.conf
              The backend configuration file (see also description of SANE_CON-
              FIG_DIR below).

       /usr/lib/x86_64-linux-gnu/sane/libsane-microtek.a
              The static library implementing this backend.

       /usr/lib/x86_64-linux-gnu/sane/libsane-microtek.so
              The  shared library implementing this backend (present on systems
              that support dynamic loading).

ENVIRONMENT
       SANE_CONFIG_DIR
              This environment variable specifies the list of directories  that
              may  contain the configuration file.  On *NIX systems, the direc-
              tories are separated by a colon (`:'), under OS/2, they are sepa-
              rated by a semi-colon (`;').  If this variable is  not  set,  the
              configuration file is searched in two default directories: first,
              the  current working directory (".") and then in /etc/sane.d.  If
              the value of the environment variable  ends  with  the  directory
              separator  character,  then  the default directories are searched
              after the explicitly specified directories.  For example, setting
              SANE_CONFIG_DIR to "/tmp/config:"  would  result  in  directories
              tmp/config, ., and /etc/sane.d being searched (in this order).

       SANE_DEBUG_MICROTEK
              If  the library was compiled with debugging support enabled, this
              environment variable controls the debug level for  this  backend.
              A  value  of 128 requests maximally copious debug output; smaller
              levels reduce verbosity.

SEE ALSO
       sane(7), sane-scsi(5), sane-microtek2(5)

AUTHOR
       Matt Marjanovic

BUGS
       Known bugs/limitations are:

              Brightness and contrast broken.
              The 600GS is grayscale only, and  will  lock  up  if  you  select
              color.  (Unfortunately, the 600GS and 600ZS are indistinguishable
              by software.)

       i.e. don't complain about these --- but if brightness and/or contrast do
       work for you, please tell me.

       If  your  scanner locks up, try setting the norealcal or noprecal option
       in the configuration file (first one, then both), and see if  it  helps.
       (If it does, report it.)

       Send    lengthy   bug   reports   and   new   scanner   information   to
       mtek-bugs@mir.com.  All bug reports and new scanner inquiries should in-
       clude an error log file.  You can generate copious stderr output by set-
       ting the SANE_DEBUG_MICROTEK environment variable described above.   For
       example:

              setenv SANE_DEBUG_MICROTEK 128

       More  general  comments,  suggestions,  and inquiries about frontends or
       SANE should go to sane-devel@alioth-lists.debian.net, the SANE  Develop-
       ers  mailing  list.  Have  a  look  at http://www.sane-project.org/mail-
       ing-lists.html concerning subscription to sane-devel.

                                  13 Jul 2008                  sane-microtek(5)