dwww Home | Manual pages | Find package

sane-mustek_pp(5)             File Formats Manual             sane-mustek_pp(5)

NAME
       sane-mustek_pp - SANE backend for Mustek parallel port flatbed scanners

DESCRIPTION
       The  sane-mustek_pp  library implements a SANE (Scanner Access Now Easy)
       backend that provides access to Mustek parallel  port  flatbed  scanners
       and OEM versions.

       There  are 2 classes of Mustek parallel port scanners: regular CCD (cold
       cathode device) scanners and CIS (contact image sensor) scanners.

       The current version of this backend supports both CCD type scanners  and
       CIS type scanners.

       The following scanners might work with this backend:

   CCD scanners
       Model:                  ASIC ID:        CCD Type:       works:
       --------------------------------------------------------------
       SE 6000 P               1013            00              yes
       SM 4800 P               1013/1015       04/01           yes
       SE 1200 ED Plus         1015            01              no
       SM 1200 ED Plus         1015            01              no
       SE 12000 P              1505            05              no
       600 III EP Plus         1013/1015       00/01           yes
       SE 600 SEP              1013            ??              yes
       600 II EP               ????            ??              no
       MD9848                  1015            00              yes
       Gallery 4800            ????            ??              yes
       Viviscan Compact II     1013            00              yes

   CIS scanners
       Model:                  ASIC ID:        works:
       -----------------------------------------------
       Mustek 600 CP & 96 CP   1015            yes (*)
       Mustek 1200 CP          1015            yes
       Mustek 1200 CP+         1015            yes

       OEM versions            Original        works
       --------------------------------------------------
       Medion/LifeTec/Tevion
          MD/LT 9350/9351      1200 CP         yes
          MD/LT 9850/9851      1200 CP         maybe (**)
          MD/LT 9858           1200 CP         probably
          MD/LT 9890/9891      1200 CP         yes
       Targa
          Funline TS12EP       1200 CP         yes
          Funline TS6EP        600 CP          yes
       Trust
          Easy Connect 9600+   600 CP          yes
       Cybercom
          9352                 1200 CP         yes (***)

       (*)     Calibration   problems existed with earlier version of this dri-
              ver. They seem to be solved now.

       (**)   Problems have been reported in the past for  the  MD/LT9850  type
              (striped  scans,  head  moving in wrong direction at some resolu-
              tions). It is not known whether the current version of the driver
              still has these problems.

       IF YOU HEAR LOUD CLICKING  NOISES,  IMMEDIATELY  UNPLUG  THE  SCANNER  !
       (This holds for any type of scanner).

       (***)   Possibly,  the  engine_delay parameter has to be set to 1 ms for
              accurate engine movements.

       Please note that this backend is still under construction. Certain  mod-
       els are currently not supported and some may never be because the commu-
       nication protocol is still unknown (eg., SE 12000 P).

       Some  scanners work faster when EPP/ECP is enabled in the BIOS. EPP mode
       however may lead to hard-locks on some Linux systems.  If  that  is  the
       case  for you, you can either disable ECP/EPP in your BIOS or disable it
       in the backend itself (see GLOBAL OPTIONS).

       Note that the backend needs to run as root or has  to  have  appropriate
       access rights to /dev/parport* if libieee1284 support is compiled in. To
       allow user access to the scanner run the backend through the network in-
       terface (see saned(8) and sane-net(5)).  Note also that the backend does
       not  support  parport  sharing, i.e. if you try printing while scanning,
       your computer may crash. To enable parport sharing, you have  to  enable
       libieee1284(3) at compile time.  You may also have to enable the backend
       explicitly  in  your  dll.conf.   Just  remove the hash mark in the line
       "mustek_pp".

DEVICE DEFINITION
       This backend allows multiple devices being defined  and  configured  via
       the  mustek_pp.conf  file  (even  simultaneously, provided that they are
       connected to different parallel ports). Please make sure  to  edit  this
       file before you use the backend.

       A device can be defined as follows:

              scanner <name> <port name> <driver>

       where

       <name>  is an arbitrary name for the device, optionally enclosed by dou-
              ble quotes, for instance "LifeTec 9350".

       <port name> is the name of the parallel port to which the device is con-
              nected. In case libieee1284 is used for  communication  with  the
              port  (default  setup),  valid port names are parport0, parport1,
              and parport2.

       In case the backend is configured for raw IO (old setup), port addresses
       have to be used instead of port names: 0x378, 0x278, or 0x3BC.  The map-
       ping of parallel ports (lp0, lp1, and lp2) to  these  addresses  can  be
       different  for different Linux kernel versions. For instance, if you are
       using a Kernel 2.2.x or better and you have only one parallel port, this
       port is named lp0 regardless of the base address. However, this  backend
       requires  the  base address of your port. If you are not sure which port
       your scanner is connected to, have a  look  at  your  /etc/conf.modules,
       /etc/modules.conf and/or /proc/ioports.

       If  you  are  unsure which port to use, you can use the magic value * to
       probe for your scanner.

       <driver> is the driver to use for this device. Currently available  dri-
              vers are:

              cis600   : for 600 CP, 96 CP & OEM versions
              cis1200  : for 1200 CP & OEM versions
              cis1200+ : for 1200 CP+ & OEM versions
              ccd300   : for 600 IIIE P & OEM version

              Choosing the wrong driver can damage your scanner!
              Especially,  using the 1200CP settings on a 600CP can be harmful.
              If the scanner starts making a loud noise, turn  it  off  immedi-
              ately !!!

       Using the cis600 driver on a 1200CP or a 1200CP+ is probably not danger-
       ous.  The  cis1200+  driver  also  works  for  the 1200CP, and using the
       cis1200 driver on a 1200CP+ will typically result in  scans  that  cover
       only half of the width of the scan area (also not dangerous).

       If  unsure  about the exact model of your OEM version, check the optical
       resolution in the manual or on the box: the 600CP has a maximum  optical
       resolution of 300x600 DPI, whereas the 1200CP and 1200CP+ have a maximum
       optical resolution of 600x1200 DPI.

       Examples:

              scanner "LifeTec 9350" 0x378 cis1200

              scanner Mustek_600CP 0x378 cis600

              scanner Mustek_600IIIEP * ccd300

       If  in  doubt which port you have to use, or whether your scanner is de-
       tected at all, you can use sane-find-scanner -p to probe all  configured
       ports.

CONFIGURATION
       The  contents of the mustek_pp.conf file is a list of device definitions
       and device options that correspond to Mustek scanners.  Empty lines  and
       lines  starting  with a hash mark (#) are ignored. Options have the fol-
       lowing format:

              option <name> [<value>]

       Depending on the nature of the  option,  a  value  may  or  may  not  be
       present.   Options  always apply to the scanner definition that precedes
       them. There are no global options. Options are also driver-specific: not
       all drivers support all possible options.

   Common options
       bw <value>
              Black/white discrimination value to be used during lineart  scan-
              ning. Pixel values below this value are assumed to be black, val-
              ues above are assumed to be white.
              Default value: 127
              Minimum:         0
              Maximum:       255

              Example:  option bw 150

   CIS driver options
       top_adjust <value>
              Vertical  adjustment  of  the  origin,  expressed  in  millimeter
              (floating point).  This option can be used to calibrate the posi-
              tion of the origin, within certain limits. Note that CIS scanners
              are probably temperature sensitive, and that a certain inaccuracy
              may be hard to avoid. Differences in offset between runs  in  the
              order of 1 to 2 mm are not unusual.
              Default value: 0.0
              Minimum:      -5.0
              Maximum:       5.0

              Example:  option top_adjust -2.5

       slow_skip
              Turns fast skipping to the start of the scan region off. When the
              region  to scan does not start at the origin, the driver will try
              to move the scanhead to the start of the scan area at the fastest
              possible speed. On some models, this may not work,  resulting  in
              large  inaccuracies (up to centimeters).  By setting this option,
              the driver is forced to use normal speed during  skipping,  which
              can  circumvent  the  accuracy  problems. Currently, there are no
              models for which these inaccuracy problems are known to occur.

              By default, fast skipping is used.

              Example:  option slow_skip

       engine_delay <value>
              Under normal circumstances, it is sufficient for  the  driver  to
              wait  for the scanner signaling that the engine is stable, before
              a new engine command can be transmitted. In rare  cases,  certain
              scanners and/or parallel port chipsets appear to prevent reliable
              detection  of  the engine state. As a result, engine commands are
              transmitted too soon and the movement of the scanner head becomes
              unreliable. Inaccuracies ranging up to 10 cm over the whole  ver-
              tical scan range have been reported. To work around this problem,
              the  engine_delay  option  can  be  set. If it is set, the driver
              waits an additional amount of time after  every  engine  command,
              equal  to  the engine_delay parameter, expressed in milliseconds.
              It practice an engine_delay of 1 ms is  usually  sufficient.  The
              maximum delay is 100 ms.

              Note  that  every additional ms of delay can add up to 14 seconds
              to the total scanning time (highest resolution), so an  as  small
              as possible value is preferred.

              Default value:   0
              Minimum:         0
              Maximum:       100

              Example:  option engine_delay 1

   CCD driver options
       top <value>
              Number  of  scanlines  to skip to the start of the scan area. The
              number can be any positive integer. Values known to me are 47 and
              56.

              Default value: 47
              Minimum:       0
              Maximum:       none

              Example:  option top 56

       waitbank <value>
              The number of usecs to wait for a bank  change.  You  should  not
              touch this value actually. May be any positive integer

              Default value: 700
              Minimum:       0
              Maximum:       none

              Example:  option waitbank 700

       A sample configuration file is shown below:

       #
       # LifeTec/Medion 9350 on port 0x378
       #
       scanner "LifeTec 9350" 0x378 cis1200

       # Some calibration options (examples!).
       option bw 127
       option top_skip -0.8

       #
       # A Mustek 600CP on port 0x3BC
       #
       scanner "Mustek 600CP" 0x3BC cis600

       # Some calibration options (examples!).
       option bw 120
       option top_skip 1.2

       #
       # A Mustek 1200CP+ on port 0x278
       #
       scanner "Mustek 1200CP plus" 0x278 cis1200+

       # Some calibration options (examples!).
       option bw 130
       option top_skip 0.2

       #
       # A Mustek 600 III EPP on port parport0
       #
       scanner "Mustek 600 III EPP" parport0 ccd300

       # Some calibration options (examples!).
       option bw 130
       option top 56

GLOBAL OPTIONS
       You  can  control  the  overall behaviour of the sane-stek_pp backend by
       global  options  which   precede   any   scanner   definition   in   the
       mustek_pp.conf file.

       Currently, there is only one global option:

   Global options
       no_epp Disable  parallel  port mode EPP: works around a known bug in the
              Linux parport code. Enable this option, if the backend hangs when
              trying to access the parallel port in EPP mode.

              Default value: use EPP

              Example:  option no_epp

FILES
       /etc/sane.d/mustek_pp.conf
              The backend configuration file (see also description of SANE_CON-
              FIG_DIR below).

       /usr/lib/x86_64-linux-gnu/sane/libsane-mustek_pp.a
              The static library implementing this backend.

       /usr/lib/x86_64-linux-gnu/sane/libsane-mustek_pp.so
              The shared library implementing this backend (present on  systems
              that support dynamic loading).

ENVIRONMENT
       SANE_CONFIG_DIR
              This  environment variable specifies the list of directories that
              may contain the configuration file.  On *NIX systems, the  direc-
              tories are separated by a colon (`:'), under OS/2, they are sepa-
              rated  by  a  semi-colon (`;').  If this variable is not set, the
              configuration file is searched in two default directories: first,
              the current working directory (".") and then in /etc/sane.d.   If
              the  value  of  the  environment variable ends with the directory
              separator character, then the default  directories  are  searched
              after the explicitly specified directories.  For example, setting
              SANE_CONFIG_DIR  to  "/tmp/config:"  would  result in directories
              tmp/config, ., and /etc/sane.d being searched (in this order).

       SANE_DEBUG_MUSTEK_PP
              If the library was compiled with debug support enabled, this  en-
              vironment  variable  controls  the  debug level for this backend.
              E.g., a value of 128 requests all debug  output  to  be  printed.
              Smaller levels reduce verbosity.

              level   debug output
              --------------------------------------
               0      nothing
               1      errors
               2      warnings & minor errors
               3      additional information
               4      debug information
               5      code flow (not supported yet)
               6      special debug information

       SANE_DEBUG_SANEI_PA4S2
              This variable sets the debug level for the SANE interface for the
              Mustek  chipset A4S2. Note that enabling this will spam your ter-
              minal with some million lines of debug output.

              level   debug output
              ----------------------------
               0      nothing
               1      errors
               2      warnings
               3      things nice to know
               4      code flow
               5      detailed code flow
               6      everything

SEE ALSO
       sane(7), sane-mustek(5),  sane-net(5),  saned(8),  sane-find-scanner(1),
       scanimage(1)

       For latest bug fixes and information see
              http://www.penguin-breeder.org/sane/mustek_pp/

       For additional information on the CIS driver, see
              http://home.scarlet.be/eddy_de_greef/

AUTHORS
       Jochen Eisinger
       <jochen at penguin-breeder dot org>
       Eddy De Greef
       <eddy_de_greef at scarlet dot be>

BUGS
       Too  many...  please  send  bug  reports  to sane-devel@alioth-lists.de-
       bian.net (note that you have to subscribe first to the list  before  you
       can send emails... see http://www.sane-project.org/mailing-lists.html).

BUG REPORTS
       If  something  doesn't work, please contact us (Jochen for the CCD scan-
       ners, Eddy for the CIS scanners). But we  need  some  information  about
       your scanner to be able to help you...

       SANE version
              Run scanimage -V to determine this.

       the backend version and your scanner hardware
              Run  SANE_DEBUG_MUSTEK_PP=128  scanimage -L as root. If you don't
              get any output from the sane-mustek_pp backend, make sure a  line
              "mustek_pp"  is included into your /etc/sane.d/dll.conf.  If your
              scanner isn't detected, make sure you've defined the  right  port
              address in your mustek_pp.conf.

       the name of your scanner/vendor also a worthy information. Please also
       include the
              optical  resolution  and  lamp  type of your scanner, both can be
              found in the manual of your scanner.

       any further comments
              if you have comments about the documentation (what could be  done
              better), or you think I should know something, please include it.

                                  13 Jul 2008                 sane-mustek_pp(5)