dwww Home | Manual pages | Find package

sane-plustek_pp(5)        SANE Scanner Access Now Easy       sane-plustek_pp(5)

NAME
       sane-plustek_pp  -  SANE backend for Plustek parallel port flatbed scan-
       ners

DESCRIPTION
       The sane-plustek_pp library implements a SANE (Scanner Access Now  Easy)
       backend  that  provides  access to Plustek ASIC 9600[1/3] and P9800[1/3]
       based parallel port flatbed scanners.

SUPPORTED DEVICES
       At present, the following scanners should work with this backend:

       PLUSTEK SCANNERS

       Parallelport Model:    ASIC: Properties:
       ---------------------- ----- ------------------------
       OpticPro PT12          98003 600x1200 dpi 36bit 512Kb
       OpticPro P12           98003 600x1200 dpi 36bit 512Kb
       OpticPro 9636T/12000T  98001 600x1200 dpi 36bit 512Kb
       OpticPro 12000P Turbo  98001 600x1200 dpi 36bit 512Kb
       OpticPro 9636P+/Turbo  98001 600x1200 dpi 36bit 512Kb
       OpticPro 9636P         96003 600x1200 dpi 36bit 128Kb
       OpticPro 12000P/96000P 96003 600x1200 dpi 36bit 128Kb
       OpticPro 1236P         96003 600x1200 dpi 30bit 128Kb
       OpticPro 9600P         96003 600x1200 dpi 30bit 128Kb
       OpticPro 9630P/FBIV    96003 600x1200 dpi 30bit 128Kb
       OpticPro 9630PL (14")  96003 600x1200 dpi 30bit 128Kb
       OpticPro A3I           96003  400x800 dpi 36bit 128Kb
       OpticPro 600P/6000P    96003  300x600 dpi 30bit  32Kb
       OpticPro 4831P         96003  300x600 dpi 30bit  32Kb
       OpticPro 4830P/FBIII   96003  300x600 dpi 30bit  32Kb
       OpticPro 4800P/FBII    96001  300x600 dpi 24bit  32Kb

       PRIMAX SCANNERS

       There are some scanners sold by Primax, but they are in fact Plustek de-
       vices. These scanners are also supported.  The following table will show
       the relationship:

       Model:                      Plustek Model:  Remarks:
       --------------------------- --------------  ------------
       Colorado 4800               OpticPro 4800   not tested
       Compact 4800 Direct         OpticPro 600    mov=2
       Compact 4800 Direct 30bit   OpticPro 4830   mov=7
       Compact 9600 Direct 30bit   OpticPro 9630   works

       GENIUS SCANNERS

       The following devices are sold as Genius Scanners, but are in fact Plus-
       tek devices.  The table will show the relationship:

       Model:                      Remarks:
       --------------------------- ----------------------------
       Colorpage Vivid III V2      Like P12 but has two buttons
                                   and Wolfson DAC

       ARIES SCANNERS

       There's one scanner sold as Aries Scanner, but is in fact a Plustek  de-
       vice.  The following table will show the relationship:

       Model:                      Plustek Model:  Remarks:
       --------------------------- --------------  ------------
       Scan-It 4800                OpticPro 600    mov=2

       BrightScan SCANNERS

       There's  one scanner sold as BrightScan OpticPro Scanner, this is also a
       rebadged Plustek device.  The following table will  show  the  relation-
       ship:

       Model:                      Remarks:
       --------------------------- ----------------------------
       BrightScan OpticPro         OpticPro P12

DEVICE NAMES
       This backend's default device is:

              0x378

       This  "default  device"  will  be  used  if no configuration file can be
       found. It is the base address of the parallel port on i386 machines.

       As the backend supports up to four devices, it is  possible  to  specify
       them in the configuration file

              /etc/sane.d/plustek_pp.conf

       See this file for examples.

CONFIGURATION
       This  section  describes  the backend's configuration file entries.  The
       file is located at: /etc/sane.d/plustek_pp.conf

       For a proper setup, you will need at least two entries:

              [direct]
              device 0x378

       direct tells the backend, that the following devicename (here 0x378) has
       to be interpreted as parallel port scanner device. In fact it is the ad-
       dress to use. Alternatively you can use /dev/parport0 if the backend has
       been compiled with libieee1284 support.

       Further options:

       option warmup t
              t specifies the warmup period in seconds

       option lampOff t
              t is the time in seconds for switching off the lamps  in  standby
              mode

       option lOffonEnd b
              b  specifies the behaviour when closing the backend, 1 --> switch
              lamps off, 0 --> do not change lamp status

       option mov m
              m is the model override switch, which only works in direct mode.

              m = 0  default: no override

              m = 1  OpticPro 9630PL override (works if  OP9630  has  been  de-
                     tected) forces legal size (14")

              m = 2  Primax  4800Direct  override  (works if OP600 has been de-
                     tected) swaps red/green color

              m = 3  OpticPro 9636 override (works if OP9636 has been detected)
                     disables backends transparency/negative capabilities

              m = 4  OpticPro 9636P override (works  if  OP9636  has  been  de-
                     tected)  disables backends transparency/negative capabili-
                     ties

              m = 5  OpticPro A3I override (works if OP12000 has been detected)
                     enables A3 scanning

              m = 6  OpticPro 4800P override (works if OP600 has been detected)
                     swaps red/green color

              m = 7  Primax 4800Direct 30bit override (works if OP4830 has been
                     detected)

       See the plustek_pp.conf file for examples.

PARALLEL PORT MODES
       The current driver works best, when the parallel port has  been  set  to
       EPP-mode.  When  detecting any other mode such as ECP or PS/2 the driver
       tries to set to a faster, supported mode. If this fails, it will use the
       SPP mode, as this mode should work with  all  Linux  supported  parallel
       ports. If in doubt, enter your BIOS and set it to any mode except ECP.

       Former  Plustek scanner models (4830, 9630) supplied a ISA parallel port
       adapter card. This card is not supported by the driver.

       The ASIC 96001/3 based models have sometimes trouble with  high  resolu-
       tion modes. If you encounter sporadic corrupted images (parts duplicated
       or shifted horizontally) kill all other applications before scanning and
       (if sufficient memory available) disable swapping.

       See the plustek_pp.conf file for examples.

FILES
       /etc/sane.d/plustek_pp.conf
              The backend configuration file

       /usr/lib/x86_64-linux-gnu/sane/libsane-plustek_pp.a
              The static library implementing this backend.

       /usr/lib/x86_64-linux-gnu/sane/libsane-plustek_pp.so
              The  shared library implementing this backend (present on systems
              that support dynamic loading).

ENVIRONMENT
       SANE_CONFIG_DIR
              This environment variable specifies the list of directories  that
              may  contain the configuration file.  On *NIX systems, the direc-
              tories are separated by a colon (`:'), under OS/2, they are sepa-
              rated by a semi-colon (`;').  If this variable is  not  set,  the
              configuration file is searched in two default directories: first,
              the  current working directory (".") and then in /etc/sane.d.  If
              the value of the environment variable  ends  with  the  directory
              separator  character,  then  the default directories are searched
              after the explicitly specified directories.  For example, setting
              SANE_CONFIG_DIR to "/tmp/config:"  would  result  in  directories
              tmp/config, ., and /etc/sane.d being searched (in this order).

       SANE_DEBUG_PLUSTEK_PP
              If  the library was compiled with debug support enabled, this en-
              vironment variable controls the debug  level  for  this  backend.
              Higher debug levels increase the verbosity of the output.

              Example: export SANE_DEBUG_PLUSTEK_PP=10

SEE ALSO
       sane(7), xscanimage(1),
       /usr/share/doc/libsane/plustek/Plustek-PARPORT.changes

CONTACT AND BUG-REPORTS
       Please send any information and bug-reports to:
       SANE Mailing List

       Additional  info and hints can be obtained from our mailing-List archive
       at: http://www.sane-project.org/mailing-lists.html.

       To obtain debug messages from the backend, please set  the  environment-
       variable  SANE_DEBUG_PLUSTEK_PP  before calling your favorite SANE fron-
       tend (e.g.  xscanimage(1)):

       export SANE_DEBUG_PLUSTEK_PP=20 ; xscanimage

       The value controls the verbosity of the output.

KNOWN BUGS & RESTRICTIONS
       * The Halftoning works, but the quality is poor

       * Printers (especially HP models) will start to print  during  scanning.
       This  in  fact  is  a problem to other printers too, using bidirectional
       protocol (see www.plustek.com (TAIWAN) page for further details)

       * The driver does not support these manic scalings up to  16  times  the
       physical resolution. The only scaling is done on resolutions between the
       physical  resolution  of  the  CCD-sensor and the stepper motor i.e. you
       have a 600x1200 dpi scanner and you are scanning using 800dpi, so  scal-
       ing  is necessary, because the sensor only delivers 600dpi but the motor
       is capable to perform 800dpi steps.

       * On some devices, the pictures seems bluish

       ASIC 98001 based models:

       * The 300dpi transparency and negative mode does not work correctly.

       * There is currently no way to distinguish  a  model  with  and  without
       transparency unit.

       * The scanned images seem to be too dark (P9636T)

       ASIC 96003/1 based models:

       * 30bit mode is currently not supported.

       *  On  low end systems under heavy system load the driver may lose data,
       which can result in picture corruption or cause the sensor  to  hit  the
       scan bed.

       * The scanning speed on 600x1200 dpi models is slow.

       * The scanning quality of the A3I is poor.

                                  14 Jul 2008                sane-plustek_pp(5)

Generated by dwww version 1.16 on Sat Oct 3 07:13:21 CEST 2026.