sane-scsi(5) SANE Scanner Access Now Easy sane-scsi(5)
NAME
sane-scsi - SCSI adapter tips for scanners
DESCRIPTION
This manual page contains various operating-system specific tips and
tricks on how to get scanners with a SCSI interface working.
GENERAL INFO
For scanners with a SCSI interface, it may be necessary to edit the ap-
propriate backend configuration file before using SANE for the first
time. For most systems, the configuration file should list the name of
the generic SCSI device that the scanner is connected to (e.g., under
Linux, /dev/sg4 or /dev/sge is such a generic SCSI device). It is cus-
tomary to create a symlink from /dev/scanner to the generic SCSI device
that the scanner is connected to. In this case, the configuration file
simply lists the line /dev/scanner. For a detailed description of each
backend's configuration file, please refer to the relevant backend man-
ual page (e.g., sane-epson(5) for Epson scanners, sane-hp(5) for HP
scanners, etc.).
For some operating systems (e.g. Linux and OS/2), there is an alternate
way of specifying scanner devices. This alternate way allows one to
identify scanners by the SCSI vendor and model string and/or by the SCSI
device address (consisting of bus number, channel number, id, and logi-
cal unit number). The syntax for specifying a scanner in this way is:
scsi VENDOR MODEL TYPE BUS CHANNEL ID LUN
where VENDOR is the SCSI vendor string, MODEL is the SCSI model string,
TYPE is the SCSI device type string, BUS is the SCSI bus number (named
"host" in /proc/scsi/scsi), CHANNEL is the SCSI channel number, ID is
the SCSI id, and LUN is the logical unit number of the scanner device.
The first two fields are strings which must be enclosed in double-quotes
if they contain any whitespace. The remaining four fields are non-nega-
tive integer numbers. The correct values for these fields can be found
by using operating system specific tools, e.g. for Linux by looking at
the output of the command cat /proc/scsi/scsi. To simplify configura-
tion, a field's value can be replaced with an asterisk symbol (``*'').
An asterisk has the effect that any value is allowed for that particular
field. This can have the effect that a single scsi-line matches multi-
ple devices. When this happens, each matching device will be probed by
the backend one by one and registered if the backend thinks it is a com-
patible device. For example, the line
scsi MUSTEK MFS-06000CX Scanner 0 00 03 00
would attach the Mustek SCSI scanner with the following /proc/scsi/scsi
entry:
Host: scsi0 Channel: 00 Id: 03 Lun: 00
Vendor: MUSTEK Model: MFS-06000CX Rev: 4.04
Type: Scanner ANSI SCSI revision: 0
Usually it's sufficient to use vendor and model strings only or even
only the vendor string. The following example
scsi MUSTEK * * * * * *
would have the effect that all SCSI devices in the system with a vendor
string of MUSTEK would be probed and recognized by the backend.
If the remainder of a scsi-string consists of asterisks only, the aster-
isks can be omitted. For example, the following line is equivalent to
the one specified previously:
scsi MUSTEK
On some platforms (e.g., OpenStep), SANE device names take a special
form. This is explained below in the relevant platform-specific sec-
tion.
When using a SCSI scanner, ensure that the access permission for the
generic SCSI device is set appropriately. We recommend to add a group
"scanner" to /etc/group which contains all users that should have access
to the scanner. The permission of the device should then be set to al-
low group read and write access. For example, if the scanner is at
generic SCSI device /dev/sg0, then the following two commands would set
the permission correctly:
$ chgrp scanner /dev/sg0
$ chmod 660 /dev/sg0
When your system uses the device filesystem (devfs), you have to edit
/etc/devfs/perms. There you should search the line
REGISTER ^sg[^/]* PERMISSIONS root.root 0600
and add a new line (eg. for changing permissions of sg4):
REGISTER ^sg4 PERMISSIONS root.scanner 0660
FREEBSD INFO
Auto-configuration using the "scsi *" lines in the config files only
works if the user running the frontend has read/write access to
/dev/xpt0. Instead, you can also set a link /dev/scanner to the appro-
priate /dev/uk device.
Adaptec AHA1542CF
Reported to work fine under FreeBSD 2.2.2R with the aha
driver.
Adaptec 2940
Reported to work fine under FreeBSD 2.2.2.
Adaptec 1522
The scanner probes ok but any attempt to access it hangs
the entire system. It looks like something is disabling
interrupts and then not re-enabling them, so it looks like
a bug in the FreeBSD aic driver.
Adaptec 1505
Works on FreeBSD 2.2.5R and 3.0 using the aic driver, pro-
vided that Plug-and-Play support is disabled on the card.
If there are no uk devices, just do a sh MAKEDEV uk0 in
the /dev directory. The scanner should then be accessible
as /dev/uk0 if it was probed during boot.
Tekram DC390
Reported to work fine under FreeBSD 2.2.2R with the amd
driver.
LINUX INFO
First, make sure your kernel has SCSI generic support enabled. In make
xconfig, this shows up under ``SCSI support->SCSI generic support''.
To keep scanning times to a minimum, it is strongly recommended to use a
large buffer size for the generic SCSI driver. From SG driver version
2.0 on, the maximum buffer size can be changed at program run time, and
there is no restriction in size. This driver version is part of the
Linux kernels from version 2.2.7 on. If the new SG driver is available
some backends (e.g. sane-umax(5), sane-mustek(5), sane-sharp(5)) auto-
matically request larger SCSI buffers. If a backend does not automati-
cally request a larger SCSI buffer, set the environment variable
SANE_SG_BUFFERSIZE to the desired buffer size in bytes. It is not recom-
mended to use more than 1 MB, because for large values the probability
increases that the SG driver cannot allocate the necessary buffer(s).
For ISA cards, even 1 MB might be a too large value. For a detailed
discussion of the Linux SG SCSI driver see: https://tldp.org/HOWTO/SCSI-
Generic-HOWTO.
For Linux kernels before version 2.2.7 the size of the buffer is only
32KB. This works, but for many cheaper scanners this causes scanning to
be slower by about a factor of four than when using a size of 127KB.
Linux defines the size of this buffer by macro SG_BIG_BUFF in header
file /usr/include/scsi/sg.h. Unless a system is seriously short on mem-
ory, it is recommended to increase this value to the maximum legal value
of 128*1024-512=130560 bytes. After changing this value, it is neces-
sary to recompile both the kernel (or the SCSI generic module) and the
SCSI backends. Keep in mind that this is only necessary with older Linux
kernels.
A common issue with SCSI scanners is what to do when you booted the sys-
tem while the scanner was turned off. In such a case, the scanner won't
be recognized by the kernel and SANE won't be able to access it. Fortu-
nately, Linux provides a simple mechanism to probe a SCSI device on de-
mand. Suppose you have a scanner connected to SCSI bus 2 and the scan-
ner has a SCSI id of 5. When the system is up and running and the scan-
ner is turned on, you can issue the command:
echo "scsi add-single-device 2 0 5 0" > /proc/scsi/scsi
and the kernel will probe and recognize your scanner (this needs to be
done as root). It's also possible to dynamically remove a SCSI device
by using the ``remove-single-device'' command. For details, please re-
fer to to the SCSI-2.4-HOWTO.
Scanners are known to work with the following SCSI adapters under Linux.
This list isn't complete, usually any SCSI adapter supported by Linux
should work.
Acard/Advance SCSI adapters
Some old versions of the kernel driver (atp870u.c) cut the
inquiry information. Therefore the scanner couldn't be
detected correctly. Use a current kernel.
Adaptec AHA-1505/AHA-1542/AHA-2940
Reported to work fine with Linux since v2.0. If you en-
counter kernel freezes or other unexpected behaviour get
the latest Linux kernel (2.2.17 seems to work) or reduce
SCSI buffer size to 32 kB.
ASUS SC200
Reported to work fine with Linux v2.0.
BusLogic BT958
To configure the BusLogic card, you may need to follow
these instructions (contributed by Jeremy <je-
remy@xxedgexx.com>): During boot, when your BusLogic
adapter is being initialized, press Ctrl-B to enter your
BusLogic adapter setup. Choose the address which your
BusLogic containing your scanner is located. Choose ``SCSI
Device Configuration''. Choose ``Scan SCSI Bus''. Choose
whatever SCSI id that contains your scanner and then
choose ``View/Modify SCSI configuration''. Change ``Nego-
tiation'' to ``async'' and change ``Disconnect'' to
``off''. Press Esc, save, and Esc again until you are
asked to reboot.
NCR/Symbios 53c400/53c400a or Domex DTC3181E/L/LE (DTCT436/436P)
ISA SCSI card
This card is supplied by Mustek (and other vendors). It's
supported since Linux 2.2. The SCSI cards are supported
by the module g_NCR5380. It's necessary to tell the ker-
nel the io port and type of card. Example for a 53c400a:
modprobe g_NCR5380 ncr_addr=0x280 ncr_53c400a=1 . Once
the kernel detects the card, it should work all right.
However, while it should work, do not expect good perfor-
mance out of this card---it has no interrupt line and
therefore while a scan is in progress, the system becomes
almost unusable. You may change the values of the USLEEP
macros in drivers/scsi/g_NCR5380.c. Some documentation is
in this file and NCR5380.c.
NCR/Symbios 810
For some scanners it may be necessary to disable discon-
nect/reconnect. To achieve this use the option
ncr53c8xx="disc:n". Some people reported that their scan-
ner only worked with the 53c7,8xx driver, not the
ncr53c8xx. Try both if you have trouble.
For Linux kernels before 2.0.33 it may be necessary to in-
crease the SCSI timeout. The default timeout for the Linux
kernels before 2.0.33 is 10 seconds, which is way too low
when scanning large area. If you get messages of the form
``restart (ncr dead ?)'' in your /var/log/messages file or
on the system console, it's an indication that the timeout
is too short. In this case, find the line ``if (np->late-
time>10)'' in file ncr53c8xx.c (normally in directory
/usr/src/linux/drivers/scsi) and change the constant 10
to, say, 60 (one minute). Then rebuild the kernel/module
and try again.
Tekram DC315
The driver can be downloaded from
http://www.garloff.de/kurt/linux/dc395/. For some older
scanners it may be necessary to disable all the more ad-
vanced features by using e.g. modprobe dc395x_trm
dc395x_trm=7,5,1,32.
Tekram DC390
Version 1.11 of the Tekram driver seems to work fine
mostly, except that the scan does not terminate properly
(it causes a SCSI timeout after 10 minutes). The generic
AM53C974 also seems to work fine and does not suffer from
the timeout problems.
SOLARIS, OPENSTEP AND NEXTSTEP INFO
Under Solaris, OpenStep and NeXTStep, the generic SCSI device name
refers to a SCSI bus, not to an individual device. For example,
/dev/sg0 refers to the first SCSI bus. To tell SANE which device to
use, append the character 'a'+target-id to the special device name. For
example, the SCSI device connected to the first SCSI controller and with
target-id 0 would be called /dev/sg0a, and the device with target-id 1
on that same bus would be called /dev/sg0b, and so on.
ENVIRONMENT
SANE_DEBUG_SANEI_SCSI
If the library was compiled with debug support enabled, this en-
vironment variable controls the debug level for the generic SCSI
I/O subsystem. E.g., a value of 128 requests all debug output to
be printed by the backend. A value of 255 also prints kernel mes-
sages from the SCSI subsystem (where available). Smaller levels
reduce verbosity.
SANE_SCSICMD_TIMEOUT
sets the timeout value for SCSI commands in seconds. Overriding
the default value of 120 seconds should only be necessary for
very slow scanners.
SEE ALSO
sane(7), sane-find-scanner(1), sane-"backendname"(5), sane-usb(5)
AUTHOR
David Mosberger
14 Jul 2008 sane-scsi(5)