NAME
       ts_calibrate - A test program to calibrate a touch screen used by tslib.

SYNOPSIS
       ts_calibrate

DESCRIPTION
       ts_calibrate is used to manually configure tslib's linear filter plugin.
       It  draws  crosshairs  to  the framebuffer to be touched by the user and
       records expected vs. actual touch contact positions needed to apply  the
       filter  and  provide  a  desired  touch  user  experience.  It  uses the
       TSLIB_CALIBFILE environment variable to store it's values.

       -r, --rotate [value]

           Rotate the screen. value is 0 for 0 degree, 1 for 90 degrees (CW), 2
           for 180 degrees (upside down) and 3  for  270  degrees  (CCW).  This
           value  will  be added to the calibration config file TSLIB_CALIBFILE
           and picked up from the linear filter module from there.  It  can  be
           changed by a linear module parameter.

       -t, --min_interval

           The  time  in  milliseconds  that  has to pass before a crosshair is
           pressed by the user. This may be useful to avoid  insanely  fast  or
           accidentally wrong taps and thus inaccurate calibration. Default: 0.

       -c, --validate

           Validate  the calibration. Make sure the linear module is configured
           in ts.conf so that the current calibration is applied. In this mode,
           crosses are displayed at random locations on screen and touches  are
           evaluated  against  their  positions.  In  this mode the --loops and
           --boundary options are available.

       -b, --boundary

           Validation boundary in pixels. Available  only  when  --validate  is
           used. This defines how strict the validation should be. It's the the
           distance that an evaluated touch input is allowed to be apart from a
           cross  to  still  pass  the validation. If this boundary is crossed,
           validation fails. Default: 10.

       -l, --loops

           Number of loops in validation mode. Available only  when  --validate
           is  used. This defines how many crosses should be touched and evalu-
           ated. Default: 3.

ENVIRONMENT VARIABLES
       see ts.conf (5)

SEE ALSO
       ts.conf (5), ts_test (1), ts_uinput (1)